Evidence map›Paper›PMID 29267305›Full record

ArticlePloS one2017

A quantitative evaluation of multiple biokinetic models using an assembled water phantom: A feasibility study.

Da-Ming Yeh, Ching-Yuan Chen, Jing-Fa Tang, Lung-Kwang Pan

Abstract read
In one paragraph

Article in PloS one, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Da-Ming YehDepartment of Diagnostic Radiology, Chung Shan Medical University Hospital, Taichung, Taiwan, ROC.
Ching-Yuan ChenGraduate Institute of Radiological Science, Central Taiwan University of Science and Technology, Takun, Taichung, Taiwan, ROC.
Jing-Fa TangGraduate Institute of Radiological Science, Central Taiwan University of Science and Technology, Takun, Taichung, Taiwan, ROC.
Lung-Kwang PanGraduate Institute of Radiological Science, Central Taiwan University of Science and Technology, Takun, Taichung, Taiwan, ROC.ORCID 0000-0003-1186-5715

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This study examined the feasibility of quantitatively evaluating multiple biokinetic models and established the validity of the different compartment models using an assembled water phantom. Most commercialized phantoms are made to survey the imaging system since this is essential to increase the diagnostic accuracy for quality assurance. In contrast, few customized phantoms are specifically made to represent multi-compartment biokinetic models. This is because the complicated calculations as defined to solve the biokinetic models and the time-consuming verifications of the obtained solutions are impeded greatly the progress over the past decade. Nevertheless, in this work, five biokinetic models were separately defined by five groups of simultaneous differential equations to obtain the time-dependent radioactive concentration changes inside the water phantom. The water phantom was assembled by seven acrylic boxes in four different sizes, and the boxes were linked to varying combinations of hoses to signify the multiple biokinetic models from the biomedical perspective. The boxes that were connected by hoses were then regarded as a closed water loop with only one infusion and drain. 129.1±24.2 MBq of Tc-99m labeled methylene diphosphonate (MDP) solution was thoroughly infused into the water boxes before gamma scanning; then the water was replaced with de-ionized water to simulate the biological removal rate among the boxes. The water was driven by an automatic infusion pump at 6.7 c.c./min, while the biological half-life of the four different-sized boxes (64, 144, 252, and 612 c.c.) was 4.8, 10.7, 18.8, and 45.5 min, respectively. The five models of derived time-dependent concentrations for the boxes were estimated either by a self-developed program run in MATLAB or by scanning via a gamma camera facility. Either agreement or disagreement between the practical scanning and the theoretical prediction in five models was thoroughly discussed. The derived biokinetic model represented the metabolic mechanism in the human body and helped to solidify the internal circulatory system into concert with numerical verification.

Indexed as

Models, TheoreticalPhantoms, ImagingDiphosphonatesFeasibility StudiesGamma CamerasHalf-LifeWaterDiphosphonatesmethylene diphosphonateWater

Identifiers

PMID29267305
PMCPMC5739403

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.