Evidence map›Paper›PMID 29255343›Full record

ArticleIEEE/ASME transactions on mechatronics : a joint publication of the IEEE Industrial Electronics Society and the ASME Dynamic Systems and Control Division2017

Iterative Jacobian-Based Inverse Kinematics and Open-Loop Control of an MRI-Guided Magnetically Actuated Steerable Catheter System.

Taoming Liu, Russell Jackson, Dominique Franson, Nate Lombard Poirot, Reinhardt Kam Criss, Nicole Seiberlich, Mark A Griswold, M Cenk Çavuşoğlu

Open access · greenAbstract read
In one paragraph

Article in IEEE/ASME transactions on mechatronics : a joint publication of the IEEE Industrial Electronics Society and the ASME Dynamic Systems and Control Division, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 15 papers.

0numbers the graph read from it
0cells of the map it votes in
15citing papers in PubMed
1.4field-weighted citation impact, top 20% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

15 citing papers in PubMed, 51 citations in OpenAlex.

  1. Article
  2. Article
  3. Free-Space Dynamic Modeling of an MRI-Actuated Robotic Catheter.IEEE/ASME transactions on mechatronics : a joint publication of the IEEE Industrial Electronics Society and the ASME Dynamic Systems and Control Division · 2025
    Article
  4. Article
  5. Design and path tracking control of a continuum robot for maxillary sinus surgery.International journal of computer assisted radiology and surgery · 2023
    Article
  6. Magnetically steerable catheters: State of the art review.Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine · 2023
    Review
  7. Article
  8. Kinematic Modeling and Jacobian-based Control of the COAST Guidewire Robot.IEEE transactions on medical robotics and bionics · 2022
    Article
  9. Review
  10. State of the Art and Future Opportunities in MRI-Guided Robot-Assisted Surgery and Interventions.Proceedings of the IEEE. Institute of Electrical and Electronics Engineers · 2022
    Article
  11. Magnetic Soft Materials and Robots.Chemical reviews · 2022
    Review
  12. A Survey on Design, Actuation, Modeling, and Control of Continuum Robot.Cyborg and bionic systems (Washington, D.C.) · 2022
    Review
  13. Article
  14. Wireless MRI-Powered Reversible Orientation-Locking Capsule Robot.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2021
    Article
  15. Analysis of Dynamic Response of an MRI-Guided Magnetically-Actuated Steerable Catheter System.Proceedings of the ... IEEE/RSJ International Conference on Intelligent Robots and Systems. IEEE/RSJ International Conference on Intelligent Robots and Systems · 2018
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 2 institutions in 1 country.

Taoming LiuCase Western Reserve University, Cleveland, Ohio 44106, USA. Department of Electrical Engineering and Computer Science.
Russell JacksonCase Western Reserve University, Cleveland, Ohio 44106, USA. Department of Electrical Engineering and Computer Science.
Dominique FransonCase Western Reserve University, Cleveland, Ohio 44106, USA. Department of Biomedical Engineering.
Nate Lombard PoirotCase Western Reserve University, Cleveland, Ohio 44106, USA. Department of Mechanical and Aerospace Engineering.
Reinhardt Kam CrissCase Western Reserve University, Cleveland, Ohio 44106, USA. Department of Electrical Engineering and Computer Science.
Nicole SeiberlichCase Western Reserve University, Cleveland, Ohio 44106, USA. Department of Biomedical Engineering.
Mark A GriswoldCase Western Reserve University, Cleveland, Ohio 44106, USA. Department of Biomedical Engineering. Department of Radiology, University Hospitals of Cleveland, Cleveland, Ohio 44106, USA.
M Cenk ÇavuşoğluCase Western Reserve University, Cleveland, Ohio 44106, USA. Department of Electrical Engineering and Computer Science.
Case Western Reserve University · USUniversity Hospitals of Cleveland · US

Funding

Improved Cardiac and Vascular MRI Using Parallel Imaging and Compressed SensingR01HL094557 · NHLBI · UNIVERSITY OF MICHIGAN AT ANN ARBOR · PI GRISWOLD, MARK, SEIBERLICH, NICOLE · 2010 to 2018
$4.5M
NRI: Small: Magnetic Resonance Imaging Guided Co-Robotic Active Catheter SystemR01EB018108 · NIBIB · CASE WESTERN RESERVE UNIVERSITY · PI CAVUSOGLU, M. CENK · 2013 to 2016
$1.3M
NHLBI NIH HHS R01 HL094557NIBIB NIH HHS R01 EB018108
6 · The paper itself

Abstract

This paper presents an iterative Jacobian-based inverse kinematics method for an MRI-guided magnetically-actuated steerable intravascular catheter system. The catheter is directly actuated by magnetic torques generated on a set of current-carrying micro-coils embedded on the catheter tip, by the magnetic field of the magnetic resonance imaging (MRI) scanner. The Jacobian matrix relating changes of the currents through the coils to changes of the tip position is derived using a three dimensional kinematic model of the catheter deflection. The inverse kinematics is numerically computed by iteratively applying the inverse of the Jacobian matrix. The damped least square method is implemented to avoid numerical instability issues that exist during the computation of the inverse of the Jacobian matrix. The performance of the proposed inverse kinematics approach is validated using a prototype of the robotic catheter by comparing the actual trajectories of the catheter tip obtained via open-loop control with the desired trajectories. The results of reproducibility and accuracy evaluations demonstrate that the proposed Jacobian-based inverse kinematics method can be used to actuate the catheter in open-loop to successfully perform complex ablation trajectories required in atrial fibrillation ablation procedures. This study paves the way for effective and accurate closed-loop control of the robotic catheter with real-time feedback from MRI guidance in subsequent research.

Indexed as

Continuum RobotsInverse KinematicsMagnetically Actuated CatheterRobotic Catheter

Identifiers

PMID29255343
PMCPMC5731790
OpenAlexW2616247830

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.