Evidence map›Paper›PMID 29255341›Full record

ArticleSensors and actuators. B, Chemical2018

Miniaturized Planar Room Temperature Ionic Liquid Electrochemical Gas Sensor for Rapid Multiple Gas Pollutants Monitoring.

Hao Wan, Heyu Yin, Lu Lin, Xiangqun Zeng, Andrew J Mason

Abstract read
In one paragraph

Article in Sensors and actuators. B, Chemical, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 16 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
16citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

16 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Sub-parts-per-billion CONature communications · 2026
    Article
  3. Article
  4. Review
  5. Review
  6. Review
  7. Review
  8. Article
  9. Review
  10. Article
  11. Review
  12. Review
  13. Review
  14. The conversion of α-pinene toRSC advances · 2019
    Article
  15. Article
  16. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Hao WanDepartment of Electrical and Computer Engineering, Michigan State University, East Lansing, MI, 48824, U.S.A.
Heyu YinDepartment of Electrical and Computer Engineering, Michigan State University, East Lansing, MI, 48824, U.S.A.
Lu LinDepartment of Chemistry, Oakland University, Rochester, MI, 48309, U.S.A.
Xiangqun ZengDepartment of Chemistry, Oakland University, Rochester, MI, 48309, U.S.A.
Andrew J MasonDepartment of Electrical and Computer Engineering, Michigan State University, East Lansing, MI, 48824, U.S.A.

Funding

Wearable Microsystem Array for Acute Pollutant Exposure AssessmentR01ES022302 · NIEHS · MICHIGAN STATE UNIVERSITY · PI MASON, ANDREW J, ZENG, XIANGQUN · 2014 to 2018
$2.3M
NIEHS NIH HHS R01 ES022302
6 · The paper itself

Abstract

The growing impact of airborne pollutants and explosive gases on human health and occupational safety has escalated the demand of sensors to monitor hazardous gases. This paper presents a new miniaturized planar electrochemical gas sensor for rapid measurement of multiple gaseous hazards. The gas sensor features a porous polytetrafluoroethylene substrate that enables fast gas diffusion and room temperature ionic liquid as the electrolyte. Metal sputtering was utilized for platinum electrodes fabrication to enhance adhesion between the electrodes and the substrate. Together with carefully selected electrochemical methods, the miniaturized gas sensor is capable of measuring multiple gases including oxygen, methane, ozone and sulfur dioxide that are important to human health and safety. Compared to its manually-assembled Clark-cell predecessor, this sensor provides better sensitivity, linearity and repeatability, as validated for oxygen monitoring. With solid performance, fast response and miniaturized size, this sensor is promising for deployment in wearable devices for real-time point-of-exposure gas pollutant monitoring.

Indexed as

Electrochemical gas sensorminiaturized sensorplanar platinum electroderoom temperature ionic liquid

Identifiers

PMID29255341
PMCPMC5731251

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.