ArticleCirculation. Arrhythmia and electrophysiology2017
Endocardial Activation Drives Activation Patterns During Long-Duration Ventricular Fibrillation and Defibrillation.
Article in Circulation. Arrhythmia and electrophysiology, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
9 citing papers in PubMed, 20 citations in OpenAlex.
- Mechanistic interpretations of sustained ventricular fibrillation: The role of mapping methodology, model and time.Heart international · 2026Review
- Validation of new AI-based classification method for in silico cardiac safety assessment of drugs following the CiPA framework.Archives of toxicology · 2025Article
- Dominant Frequency of Ventricular Fibrillation During Ischemia and Reperfusion.Bulletin of experimental biology and medicine · 2024Article
- Distinct spectral dynamics of implanted cardiac defibrillator signals in spontaneous termination of polymorphic ventricular tachycardia and fibrillation in patients with electrical and structural diseases.Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2022Article
- During Early VF in Rabbit Hearts, His Bundle Pacing is Less Effective Than Working Myocardial Pacing in Modulating Left Ventricular Activation Rates.Cardiovascular engineering and technology · 2022Article
- Termination of long-duration ventricular fibrillation by catheter ablation.HeartRhythm case reports · 2020Article
- A real-time system for selectively sensing and pacing the His-bundle during sinus rhythm and ventricular fibrillation.Biomedical engineering online · 2020Article
- Elimination of Purkinje Fibers by Electroporation Reduces Ventricular Fibrillation Vulnerability.Journal of the American Heart Association · 2018Article
- Ventricular Fibrillation: Rotors or Foci? Both!Circulation. Arrhythmia and electrophysiology · 2017Article
Corrections and comments
- Commented on by
Authors and funding
6 authors at 1 institution in 1 country.
Funding
Abstract
backgroundUnderstanding the mechanisms that drive ventricular fibrillation is essential for developing improved defibrillation techniques to terminate ventricular fibrillation (VF). Distinct organization patterns of chaotic, regular, and synchronized activity were previously demonstrated in VF that persisted over 1 to 2 minutes (long-duration VF [LDVF]). We hypothesized that activity on the endocardium may be driving these activation patterns in LDVF and that unsuccessful defibrillation shocks may alter activation patterns. METHODS AND
resultsThe study was performed using a 64-electrode basket catheter on the left ventricle endocardium and 54 6-electrode plunge needles inserted into the left ventricles of 6 dogs. VF was induced electrically, and after short-duration VF (10 seconds) and LDVF (7 minutes), shocks of increasing strengths were delivered every 10 seconds until VF was terminated. Endocardial activation patterns were classified as chaotic (varying cycle lengths and nonsynchronous activations), regular (highly repeatable cycle lengths), and synchronized (activation that spreads rapidly over the endocardium with diastolic periods between activations).
conclusionsThe results showed that the chaotic pattern was predominant in early VF, but the regular pattern emerges as VF progressed. The synchronized pattern only emerged occasionally during late VF. Failed defibrillation shocks changed chaotic and regular activation patterns to synchronized patterns in LDVF but not in short-duration VF. The regular and synchronized patterns of activation were driven by rapid activations on the endocardial surface that blocked and broke up transmurally, leading to an endocardial to epicardial activation rate gradient as LDVF progressed.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.