ArticleJournal of neurosurgery2018
Stereotactic EEG via multiple single-path omnidirectional trajectories within a single platform: institutional experience with a novel technique.
Article in Journal of neurosurgery, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
9 citing papers in PubMed, 1 synthesis or guideline pooled it, 21 citations in OpenAlex.
- Seizure outcomes and complications associated with stereoelectroencephalography versus subdural electrodes for invasive monitoring in epilepsy surgery: a meta-analysis.Frontiers in neurology · 2025Pooled it
- Clinical Applicability and Safety of Conventional Frame-Based Stereotactic Techniques for Stereoelectroencephalography.Journal of Korean Neurosurgical Society · 2024Article
- Studying memory processes at different levels with simultaneous depth and surface EEG recordings.Frontiers in human neuroscience · 2023Article
- Imaging the effective networks associated with cortical function through intracranial high-frequency stimulation.Human brain mapping · 2022Article
- VarioGuide® frameless neuronavigation-guided stereoelectroencephalography in adult epilepsy patients: technique, accuracy and clinical experience.Acta neurochirurgica · 2021Article
- Extracting seizure onset from surface EEG with independent component analysis: Insights from simultaneous scalp and intracerebral EEG.NeuroImage. Clinical · 2021Article
- Resting-State SEEG May Help Localize Epileptogenic Brain Regions.Neurosurgery · 2020Article
- Illusory own body perceptions mapped in the cingulate cortex-An intracranial stimulation study.Human brain mapping · 2019Article
- Stereoelectroencephalography in epilepsy, cognitive neurophysiology, and psychiatric disease: safety, efficacy, and place in therapy.Neuropsychiatric disease and treatment · 2019Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
12 authors at 4 institutions in 1 country.
Funding
Abstract
OBJECTIVEStereotactic electroencephalography (SEEG) is being used with increasing frequency to interrogate subcortical, cortical, and multifocal epileptic foci. The authors describe a novel technique for SEEG in patients with suspected epileptic foci refractory to medical management.METHODSIn the authors' technique, standard epilepsy evaluation and neuroimaging are used to create a hypothesis-driven SEEG plan, which informs the 3D printing of a novel single-path, multiple-trajectory, omnidirectional platform. Following skull-anchor platform fixation, electrodes are sequentially inserted according to the preoperative plan. The authors describe their surgical experience and technique based on a review of all cases, adult and pediatric, in which patients underwent invasive epilepsy monitoring via SEEG during an 18-month period at Vanderbilt University Medical Center. Platform and anatomical variables influencing localization error were evaluated using multivariate linear regression.RESULTSUsing this novel technology, 137 electrodes were inserted in 15 patients with focal epilepsy with favorable recording results and no clinical complications. The mean entry point localization error was 1.42 mm (SD 0.98 mm), and the mean target point localization error was 3.36 mm (SD 2.68 mm). Platform distance, electrode trajectory angle, and intracranial distance, but not skull thickness, were independently associated with localization error.CONCLUSIONSThe multiple-trajectory, single-path, omnidirectional platform offers satisfactory accuracy and favorable clinical results, while avoiding cumbersome frames and prohibitive up-front costs associated with other SEEG technologies.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.