Evidence map›Paper›PMID 29239963›Full record

ArticleAnesthesia and analgesia2018

In Vitro Evaluation of a Novel Image Processing Device to Estimate Surgical Blood Loss in Suction Canisters.

Gerhardt Konig, Jonathan H Waters, Eric Hsieh, Bridget Philip, Vicki Ting, Gaurav Abbi, Mazyar Javidroozi, Griffeth W Tully, Gregg Adams

Open access · greenAbstract read
In one paragraph

Article in Anesthesia and analgesia, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed, 2 pooled it
1.5field-weighted citation impact, top 19% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed, 2 syntheses or guidelines pooled it, 25 citations in OpenAlex.

  1. Pooled it
  2. Pooled it
  3. Review
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 4 institutions in 1 country.

Gerhardt KonigFrom the Departments of Anesthesiology.
Jonathan H WatersAnesthesiology and Bioengineering, University of Pittsburgh School of Medicine, Pittsburgh, Pennsylvania.
Eric HsiehGauss Surgical, Inc, Los Altos, California.
Bridget PhilipDepartments of Anesthesiology.
Vicki TingObstetrics.
Gaurav AbbiOrthopedics, Santa Clara Valley Medical Center, San Jose, California.
Mazyar JavidrooziEnglewood Hospital and Medical Center, Englewood, New Jersey.
Griffeth W TullyGauss Surgical, Inc, Los Altos, California.
Gregg AdamsDepartment of Surgery, Santa Clara Valley Medical Center, San Jose, California.
Englewood Hospital and Medical Center · USMcGowan Institute for Regenerative Medicine · USSanta Clara Valley Medical Center · USUniversity of Pittsburgh · US

Funding

Research Training in Anesthesiology and Pain MedicineT32GM075770 · NIGMS · UNIVERSITY OF PITTSBURGH AT PITTSBURGH · PI YAN XU · 2007 to 2026
$4.8M
NIGMS NIH HHS T32 GM075770
6 · The paper itself

Abstract

backgroundClinicians are tasked with monitoring surgical blood loss. Unfortunately, there is no reliable method available to assure an accurate result. Most blood lost during surgery ends up on surgical sponges and within suction canisters. A novel Food and Drug Administration-cleared device (Triton system; Gauss Surgical, Inc, Los Altos, CA) to measure the amount of blood present on sponges using computer image analysis has been previously described. This study reports on performance of a complementary Food and Drug Administration-cleared device (Triton Canister System; Gauss Surgical, Inc, Los Altos, CA) that uses similar image analysis to measure the amount of blood in suction canisters.

methodsKnown quantities of expired donated whole blood, packed red blood cells, and plasma, in conjunction with various amounts of normal saline, were used to create 207 samples representing a wide range of blood dilutions commonly seen in suction canisters. Each sample was measured by the Triton device under 3 operating room lighting conditions (bright, medium, and dark) meant to represent a reasonable range, resulting in a total of 621 measurements. Using the Bland-Altman method, the measured hemoglobin (Hb) mass in each sample was compared to the results obtained using a standard laboratory assay as a reference value. The analysis was performed separately for samples measured under each lighting condition. It was expected that under each separate lighting condition, the device would measure the various samples within a prespecified clinically significant Hb mass range (±30 g per canister).

resultsThe limits of agreement (LOA) between the device and the reference method for dark (bias: 4.7 g [95% confidence interval {CI}, 3.8-5.6 g]; LOA: -8.1 g [95% CI, -9.7 to -6.6 g] to 17.6 g [95% CI, 16.0-19.1 g]), medium (bias: 3.4 g [95% CI, 2.6-4.1 g]; LOA: -7.4 g [95% CI, -8.7 to -6.1 g] to 14.2 g [95% CI, 12.9-15.5 g]), and bright lighting conditions (bias: 4.1 g [95% CI, 3.2-4.9 g]; LOA: -7.6 g [95% CI, -9.0 to -6.2 g] to 15.7 g [95% CI, 14.3-17.1 g]) fell well within the predetermined clinically significant limits of ±30 g. Repeated measurements of the samples under the various lighting conditions were highly correlated with intraclass correlation coefficient of 0.995 (95% CI, 0.993-0.996; P < .001), showing that lighting conditions did not have a significant impact on measurements. Hb mass bias was significantly associated with hemolysis level (Spearman ρ correlation coefficient, -0.137; P = .001) and total canister volume (Spearman ρ correlation coefficient, 0.135; P = .001), but not ambient illuminance.

conclusionsThe Triton Canister System was able to measure the Hb mass reliably with clinically acceptable accuracy in reconstituted blood samples representing a wide range of Hb concentrations, dilutions, hemolysis, and ambient lighting settings.

Indexed as

Blood Loss, SurgicalHemoglobinometryHemoglobinsHemolysisHumansImage Processing, Computer-AssistedMonitoring, IntraoperativeSpectrophotometrySuctionSurgical SpongesHemoglobins

Identifiers

PMID29239963
PMCPMC5884116
OpenAlexW2772973553

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.