Trial reportTrials2017
Self-expanding nitinol stents of high versus low chronic outward force in de novo femoropopliteal occlusive arterial lesions (BIOFLEX-COF trial): study protocol for a randomized controlled trial.
Trial report in Trials, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT03097679 (Self-expanding Nitinol Stents of High vs. Low Chronic Outward Force in De-novo Femoropopliteal Occlusive Arterial Lesions), which is not on this map. Cited by 7 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Self-expanding Nitinol Stents of High vs. Low Chronic Outward Force in De-novo Femoropopliteal Occlusive Arterial Lesions
Who cites it
7 citing papers in PubMed, 15 citations in OpenAlex.
- Trial
- Numerical Evaluation of a Zero Poisson's Ratio Structure in µ-3D-Printed Self-Expanding Nitinol Stents.Micromachines · 2026Article
- Computational Optimization of a Stent for the Femoropopliteal Artery.Annals of biomedical engineering · 2026Article
- Idiopathic Intracranial Hypertension Animal Models and Venous Sinus Stenting: Status of Disease and Device-Focused Evidence.Brain sciences · 2025Review
- Article
- Heterogeneous vascular response after implantation of bare nitinol self-expanding stents in the swine femoropopliteal artery.Cardiovascular intervention and therapeutics · 2023Article
- [Biomechanical study of nickel-titanium three-dimensional memory alloy mesh and autologous bone in treatment of canine tibial plateau collapse fracture].Zhongguo xiu fu chong jian wai ke za zhi = Zhongguo xiufu chongjian waike zazhi = Chinese journal of reparative and reconstructive surgery · 2018Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundSelf-expanding nitinol stents must be oversized at least by a minimal amount to ensure contact with the vessel wall and prevent migration. Once the stent is deployed it exerts a continuous force upon the vascular wall, termed chronic outward force (COF). Animal studies have found an increased neointimal hyperplasia in stents with high oversizing and thus high COF. Data about correlation between COF and neointimal hyperplasia in humans are currently lacking. The objective of the BIOFLEX-COF trial is to prospectively investigate differences in formation of intimal hyperplasia at 1 and 2 years after implantation of nitinol stents with high versus low COF in de novo femoropopliteal occlusive arterial lesions.
methodsThe BIOFLEX-COF trial is a prospective, quantitative, randomized study. Eighty subjects with symptomatic peripheral arterial lesions eligible for endovascular stent implantation will be enrolled and randomly assigned to either a high COF group (LifeStent Flexstar, Bard Peripheral Vascular Inc., Tempe, AZ, USA) or low COF group (Pulsar, Biotronik AG, Bülach, Switzerland) using an online randomization program to generate a random 1:1 group allocation (block randomization). After implantation and dilatation, COF at every 2 mm along the stent axis will be calculated from the actual stent diameter versus its nominal diameter. There will be two follow-up evaluations at 12 and 24 months. Primary endpoint is the amount of in-stent neointima at 1 year, assessed by contrast-enhanced CT angiography (CTA). In the control examinations, stent diameter and true lumen diameter will be measured on DICOM images every 2 mm along the stent axis to quantify the relative amount of in-stent restenosis. Secondary objectives are the amount of in-stent neointima at 2 years, device- and procedure-related adverse events and target lesion revascularization (TLR) rate. The scheduled time for recruitment is 2 years. Recruitment is expected to be complete in October 2017. DISCUSSION: This trial is the first to prospectively investigate the influence of COF on stent patency. If successful, the results will aid in a more precise selection of stent type and size in a given target vessel. The present study is challenging in that it compares two different self-expanding nitinol stents head-to-head against each other. To optimize the power of this study, traditional binary outcome parameters such as TLR and restenosis at Doppler ultrasound were dropped as primary endpoints. Instead, the amount of neointima inside the stent accessed by CTA was selected as (continuous) outcome parameter.
trial registrationClinicalTrials.gov Identifier: NCT03097679 . Date of registration: 14 March 2017 (retrospectively registered).
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.