ArticleJournal of diabetes science and technology2018
The Effect of Continuous Glucose Monitoring in Preventing Inpatient Hypoglycemia in General Wards: The Glucose Telemetry System.
Article in Journal of diabetes science and technology, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to 2 registered trials, which are not on this map. Cited by 37 papers, 2 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Continuous Glucose Monitoring of Hospitalized Patients With Diabetes: A Pilot Study to Establish Evidence
Does the Use of Continuous Glucose Monitoring (CGM) in the Immediate Postpartum Period in Women With Pregestational Diabetes Admitted to the Hospital Decrease Hypoglycemic Episodes
Who cites it
37 citing papers in PubMed, 2 syntheses or guidelines pooled it, 65 citations in OpenAlex.
- American Association of Clinical Endocrinology Clinical Practice Guideline: Developing a Diabetes Mellitus Comprehensive Care Plan-2022 Update.Endocrine practice : official journal of the American College of Endocrinology and the American Association of Clinical Endocrinologists · 2022Guideline
- Continuous Glucose Monitors and Automated Insulin Dosing Systems in the Hospital Consensus Guideline.Journal of diabetes science and technology · 2020Guideline
- Results From a Randomized Trial of Intensive Glucose Management Using CGM Versus Usual Care in Hospitalized Adults With Type 2 Diabetes: The TIGHT Study.Diabetes care · 2025Trial
- Continuous Glucose Monitoring-Guided Insulin Administration in Hospitalized Patients With Diabetes: A Randomized Clinical Trial.Diabetes care · 2022Trial
- Remote Continuous Glucose Monitoring With a Computerized Insulin Infusion Protocol for Critically Ill Patients in a COVID-19 Medical ICU: Proof of Concept.Diabetes care · 2021Trial
- Continuous Glucose Monitoring in General Wards for Prevention of Hypoglycemia: Results From the Glucose Telemetry System Pilot Study.Journal of diabetes science and technology · 2020Trial
- An international position statement on practical approaches for inpatient continuous glucose monitoring, insulin pumps and automated insulin delivery systems in adults.Diabetologia · 2026Article
- Consensus Considerations and Good Practice Points for Use of Continuous Glucose Monitoring Systems in Hospital Settings.Diabetes care · 2024Review
- Review Article - Diabetes Technology in the Hospital: An Update.Current diabetes reports · 2024Review
- A Consensus Statement for Continuous Glucose Monitoring Metrics for Inpatient Clinical Trials.Journal of diabetes science and technology · 2023Article
- Expert Recommendations for Using Time-in-Range and Other Continuous Glucose Monitoring Metrics to Achieve Patient-Centered Glycemic Control in People With Diabetes.Journal of diabetes science and technology · 2023Review
- Accuracy of Continuous Glucose Monitors for Inpatient Diabetes Management.Journal of diabetes science and technology · 2023Article
- Use of Continuous Glucose Monitoring in Non-ICU Hospital Settings for People With Diabetes: A Scoping Review of Emerging Benefits and Issues.Journal of diabetes science and technology · 2023Article
- Stress and human health in diabetes: A report from the 19Journal of clinical and translational science · 2023Article
- Artificial Intelligence for Predicting and Diagnosing Complications of Diabetes.Journal of diabetes science and technology · 2023Article
- Hospital Diabetes Meeting 2022.Journal of diabetes science and technology · 2022Article
- Machine Learning Models for Inpatient Glucose Prediction.Current diabetes reports · 2022Review
- Update on the management of diabetes in long-term care facilities.BMJ open diabetes research & care · 2022Review
- Feasibility of Real-Time Continuous Glucose Monitoring Telemetry System in an Inpatient Diabetes Unit: A Pilot Study.Journal of diabetes science and technology · 2022Article
- Use of a Continuous Glucose Monitoring System in High-Risk Hospitalized Noncritically Ill Patients With Diabetes After Cardiac Surgery and During Their Transition of Care From the Intensive Care Unit During COVID-19: A Pilot Study.Endocrine practice : official journal of the American College of Endocrinology and the American Association of Clinical Endocrinologists · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors at 3 institutions in 1 country.
Funding
Abstract
backgroundFew studies have examined the use of continuous glucose monitoring (CGM) devices in the general wards. The aim of this pilot study was to examine whether CGM readings can be successfully transmitted from the bedside to a central monitoring device in the nursing station, and whether a glucose telemetry system can prevent hypoglycemic events.
methodsWe present pilot data on 5 consecutive insulin treated general medicine patients with type 2 diabetes (T2DM) whose glucose values were observed with CGM (DEXCOM) and the results were transmitted to a central nursing station monitoring system using DEXCOM Follow and Share 2 software. CGM alarms were set-up at glucose <85 mg/dl.
resultsDuration of CGM observation was 4.0 ± 1.6 days (mean ± SD). During CGM, the overall time spent within blood glucose (BG) target of 70-179 mg/dl was 64.68 ± 15% (mean ± SD), on hypoglycemia (<70 mg/dl) was 0.30% ± 0.39, and time spent on hyperglycemia (≥180 mg/dl) was 35.02% ± 15.5. Two patients had 3 actions of prevention of potential hypoglycemia (CGM BG <70 mg/dl for >20 minutes) captured by alarm. No patients had CGM glucose value <54 mg/dl.
conclusionsThis pilot study indicates that the use of CGM values in hospitalized patients can be successfully transmitted to a monitoring device in the nursing station, improving patient surveillance in insulin treated patients with diabetes.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.