Evidence map›Paper›PMID 29230871›Full record

ArticleMagnetic resonance in medicine2018

Prospective motion correction enables highest resolution time-of-flight angiography at 7T.

Hendrik Mattern, Alessandro Sciarra, Frank Godenschweger, Daniel Stucht, Falk Lüsebrink, Georg Rose, Oliver Speck

Abstract read
In one paragraph

Article in Magnetic resonance in medicine, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 25 papers.

0numbers the graph read from it
0cells of the map it votes in
25citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

25 citing papers in PubMed.

  1. Article
  2. Article
  3. High-resolution 0.16-mm time-of-flight angiography at 7 T with volumetric navigators for prospective motion correction.Proceedings of the International Society for Magnetic Resonance in Medicine ... Scientific Meeting and Exhibition. International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition · 2025
    Article
  4. Enlarged perivascular spaces in the basal ganglia are associated with arteries not veins.Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism · 2024
    Article
  5. Article
  6. Review
  7. Image-based hemodynamic simulations for intracranial aneurysms: the impact of complex vasculature.International journal of computer assisted radiology and surgery · 2024
    Article
  8. Article
  9. Review
  10. Review
  11. Article
  12. Article
  13. Neuroimaging at 7 Tesla: a pictorial narrative review.Quantitative imaging in medicine and surgery · 2022
    Review
  14. Article
  15. Article
  16. Article
  17. Article
  18. Review
  19. Article
  20. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Hendrik MatternDepartment of Biomedical Magnetic Resonance, Institute of Experimental Physics, Otto-von-Guericke-University, Magdeburg, Germany.
Alessandro SciarraDepartment of Biomedical Magnetic Resonance, Institute of Experimental Physics, Otto-von-Guericke-University, Magdeburg, Germany.
Frank GodenschwegerDepartment of Biomedical Magnetic Resonance, Institute of Experimental Physics, Otto-von-Guericke-University, Magdeburg, Germany.
Daniel StuchtDepartment of Biomedical Magnetic Resonance, Institute of Experimental Physics, Otto-von-Guericke-University, Magdeburg, Germany.
Falk LüsebrinkDepartment of Biomedical Magnetic Resonance, Institute of Experimental Physics, Otto-von-Guericke-University, Magdeburg, Germany.
Georg RoseChair for Healthcare Telematics and Medical Engineering, Otto-von-Guericke-University, Magdeburg, Germany.
Oliver SpeckDepartment of Biomedical Magnetic Resonance, Institute of Experimental Physics, Otto-von-Guericke-University, Magdeburg, Germany.

Funding

RGR-based motion tracking for real-time adaptive MR imaging and spectroscopyR01DA021146 · NIDA · UNIVERSITY OF MARYLAND BALTIMORE · PI ERNST, THOMAS M · 2007 to 2018
$8.6M
NIDA NIH HHS R01 DA021146
6 · The paper itself

Abstract

purposeHigher magnetic field strengths enable time-of-flight (TOF) angiography with higher resolution to depict small-vessel pathologies. However, this potential is limited by the subject's ability to remain motionless. Even small-scale, involuntary motion can degrade vessel depiction, thus limiting the effective resolution. The aim of this study was to overcome this resolution limit by deploying prospectively motion-corrected (PMC) TOF.

methodsAn optical, marker-based, in-bore tracking system was used to update the imaging volume prospectively according to the subject's head motion. PMC TOF was evaluated in 12 healthy, cooperative subjects at isotropic resolution of up to 150 μm. Image quality was assessed qualitatively through reader rating and quantitatively with the average edge-strength metric.

resultsPMC significantly increased the average edge strength and qualitatively improved the vessel depiction in nine out of 11 cases. Image quality was never degraded by motion correction. PMC also enabled acquisition of the highest resolution human brain in vivo TOF angiography to date.

conclusionWith PMC enabled, high-resolution TOF is able to visualize brain vasculature beyond the effective resolution limit. Magn Reson Med 80:248-258, 2018. © 2017 International Society for Magnetic Resonance in Medicine.

Indexed as

MotionAdultAlgorithmsAngiography, Digital SubtractionArtifactsBrainHealthy VolunteersHumansImage Interpretation, Computer-AssistedImage Processing, Computer-AssistedImaging, Three-DimensionalMagnetic Resonance AngiographyMaleModels, StatisticalMovementPhantoms, Imaginghigh-resolution MRIlenticulostriate arteriesprospective motion correctionsparse saturationtime-of-flight angiographyultrahigh field

Identifiers

PMID29230871
PMCPMC5876090

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.