ArticlePeerJ2017
Comparison between radial artery tonometry pulse analyzer and pulsed-Doppler echocardiography derived hemodynamic parameters in cardiac surgery patients: a pilot study.
Article in PeerJ, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
11 citing papers in PubMed, 22 citations in OpenAlex.
- A Real-Time Antifouling Multivalent Aptamer Platform for Wash-Free Electrochemical Detection of Low-Abundance Biomarkers in Human Plasma.Angewandte Chemie (International ed. in English) · 2026Article
- Observational
- Novel Pulse Waveform Index by Ambulatory Blood Pressure Monitoring and Cardiac Function: A Pilot Study.JACC. Advances · 2024Article
- Development of a Direct Non-Puncture Device for Measuring Portal Venous Pressure during Liver Transplantation-A Swine Model.Biosensors · 2023Article
- Mechanical Sensors for Cardiovascular Monitoring: From Battery-Powered to Self-Powered.Biosensors · 2022Review
- Biomechanical Sensing Systems for Cardiac Activity Monitoring.International journal of biomaterials · 2022Review
- Technological Assessment and Objective Evaluation of Minimally Invasive and Noninvasive Cardiac Output Monitoring Systems.Anesthesiology · 2020Review
- Stroke volume and cardiac output measurement in cardiac patients during a rehabilitation program: comparison between tonometry, impedancemetry and echocardiography.The international journal of cardiovascular imaging · 2020Article
- Development of a Multi-Array Pressure Sensor Module for Radial Artery Pulse Wave Measurement.Sensors (Basel, Switzerland) · 2019Article
- [Principles and pitfalls of arterial blood pressure measurement].Der Anaesthesist · 2019Article
- Accuracy of non-invasive and minimally invasive hemodynamic monitoring: where do we stand?Annals of translational medicine · 2019Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
11 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundBedside non-invasive techniques, such as radial artery tonometry, to estimate hemodynamic parameters have gained increased relevance as an attractive alternative and efficient method to measure hemodynamics in outpatient departments. For our pilot study, we sought to compare cardiac output (CO), and stroke volume (SV) estimated from a radial artery tonometry blood pressure pulse analyzer (BPPA) (DMP-Life, DAEYOMEDI Co., Gyeonggi-do, South Korea) to pulsed-wave Doppler (PWD) echocardiography derived parameters.
methodsFrom January 2015 to December 2016, all patients scheduled for coronary artery bypass (CABG) surgery at our department were screened. Exclusion criteria were, inter alia, moderate to severe aortic- or Mitral valve disease and peripheral arterial disease (PAD) > stage II. One hundred and seven patients were included (mean age 66.1 ± 9.9, 15 females, mean BMI 27.2 ± 4.1 kg/m
resultsMean TTE-CO was 5.1 ± 0.96 L/min, and the mean BPPA-CO was 5.2 ± 0.85 L/min. The Bland-Altman analysis for CO revealed a bias of -0.13 L/min and SD of 0.90 L/min with upper and lower limits of agreement of -1.91 and +1.64 L/min. The correlation of CO measurements between DMP-life and TTE was poor (
conclusionOur study shows for the first time that the DMP-life tonometry device measures SV and CO with reasonable accuracy and precision of agreement compared with TTE in preoperative cardiothoracic surgery patients. Tonometry BPPA are relatively quick and simple measuring devices, which facilitate the collection of cardiac and hemodynamic information. Further studies with a larger number of patients and with repeated measurements are in progress to test the reliability and repeatability of DMP-Life system.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.