Comparison of electrohysterogram signal measured by surface electrodes with different designs: A computational study with dipole band and abdomen models.

Pei Gao, Dongmei Hao, Yang An, Ying Wang, Qian Qiu, Lin Yang, Yimin Yang, Song Zhang, Xuwen Li, Dingchang Zheng

Open access · goldAbstract readComparative Study
In one paragraph

Article in Scientific reports, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.4field-weighted citation impact, top 38% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 7 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 2 institutions in 2 countries.

Pei GaoCollege of Life Science and Bioengineering, Beijing University of Technology, Beijing, 100124, China.
Dongmei HaoCollege of Life Science and Bioengineering, Beijing University of Technology, Beijing, 100124, China. haodongmei@bjut.edu.cn.
Yang AnCollege of Life Science and Bioengineering, Beijing University of Technology, Beijing, 100124, China.
Ying WangCollege of Life Science and Bioengineering, Beijing University of Technology, Beijing, 100124, China.
Qian QiuCollege of Life Science and Bioengineering, Beijing University of Technology, Beijing, 100124, China.
Lin YangCollege of Life Science and Bioengineering, Beijing University of Technology, Beijing, 100124, China.
Yimin YangCollege of Life Science and Bioengineering, Beijing University of Technology, Beijing, 100124, China.
Song ZhangCollege of Life Science and Bioengineering, Beijing University of Technology, Beijing, 100124, China.
Xuwen LiCollege of Life Science and Bioengineering, Beijing University of Technology, Beijing, 100124, China.
Dingchang ZhengHealth and Wellbeing Academy, Faculty of Medical Science, Anglia Ruskin University, Chelmsford, CM1 1SQ, UK. dingchang.zheng@anglia.ac.uk.
Beijing University of Technology · CNAnglia Ruskin University · GB

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Non-invasive measurement of uterine activity using electrohysterogram (EHG) surface electrodes has been attempted to monitor uterine contraction. This study aimed to computationally compare the performance of acquiring EHG signals using monopolar electrode and three types of Laplacian concentric ring electrodes (bipolar, quasi-bipolar and tri-polar). With the implementation of dipole band model and abdomen model, the performances of four electrodes in terms of the local sensitivity were quantified by potential attenuation. Furthermore, the effects of fat and muscle thickness on potential attenuation were evaluated using the bipolar and tri-polar electrodes with different radius. The results showed that all the four types of electrodes detected the simulated EHG signals with consistency. That the bipolar and tri-polar electrodes had greater attenuations than the others, and the shorter distance between the origin and location of dipole band at 20 dB attenuation, indicating that they had relatively better local sensitivity. In addition, ANOVA analysis showed that, for all the electrodes with different outer ring radius, the effects of fat and muscle on potential attenuation were significant (all p < 0.01). It is therefore concluded that the bipolar and tri-polar electrodes had higher local sensitivity than the others, indicating that they can be applied to detect EHG effectively.

Indexed as

ElectrodesElectrophysiological PhenomenaAbdomenComputer SimulationElectromyographyFemaleHumansMonitoring, PhysiologicPregnancyUterine MonitoringUterus

Identifiers

PMID29229922
PMCPMC5725603
OpenAlexW2773870676

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.