SynthesisHypertension (Dallas, Tex. : 1979)2018
Accuracy of Blood Pressure Measurement Devices in Pregnancy: A Systematic Review of Validation Studies.
Synthesis in Hypertension (Dallas, Tex. : 1979), 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT05676476 (The ACHIEVE Trial), which is not on this map. Cited by 58 papers, 2 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
The ACHIEVE Trial: Achieving Longer Gestation in Preeclampsia Via Antihypertensive Therapy.
Who cites it
58 citing papers in PubMed, 2 syntheses or guidelines pooled it, 120 citations in OpenAlex.
- Setting and techniques for monitoring blood pressure during pregnancy.The Cochrane database of systematic reviews · 2020Pooled it
- Pooled it
- Feasibility of multi-component intervention for blood pressure control in pregnancy in Nigeria and Ghana: a pilot randomized clinical trial.BMC pregnancy and childbirth · 2026Trial
- Effect of educational intervention based on the theory of planned behavior (TPB) on amount of salt intake in pregnant women with PreHypertension.BMC women's health · 2024Trial
- Pre-Eclampsia and Maternal Cardiovascular Function: Insights Into Pathophysiology and Care (Scientific Impact Paper No. 79).BJOG : an international journal of obstetrics and gynaecology · 2026Article
- Cardiometabolic Health in Pregnancy: Prevention, Management, and Long-Term Implications.JACC. Advances · 2026Review
- Cuffless Devices for the Measurement of Blood Pressure: A Scientific Statement From the American Heart Association.Hypertension (Dallas, Tex. : 1979) · 2026Review
- Evaluating a Smartphone App to Monitor Blood Pressure in Normotensive Pregnancies, High-Risk Pregnancies, and Women With Preeclampsia: Prospective Longitudinal Feasibility Study.JMIR human factors · 2026Article
- The Japanese Society of Hypertension Guidelines for the management of elevated blood pressure and hypertension 2025 (JSH2025).Hypertension research : official journal of the Japanese Society of Hypertension · 2026Article
- Lack of validated blood pressure devices for use in pregnancy available from Australian pharmacies.Hypertension research : official journal of the Japanese Society of Hypertension · 2025Article
- Perspectives of Ghanaian pregnant women on family involvement in home blood pressure Monitoring: A qualitative analysis.Pregnancy hypertension · 2025Article
- Cardiac Biomarkers in Pregnancies With and Without Hypertension.American journal of hypertension · 2025Article
- Advancing equity with technology and innovation in obstetrics: A critical approach to obstetricPregnancy (Hoboken, N.J.) · 2025Review
- Perceived, objective, and applied numeracy among pregnant women engaged in home blood pressure monitoring in Ghana.AJOG global reports · 2025Article
- Optimization of Ambulatory Blood Pressure Monitoring during Pregnancy: A Path Toward Risk Stratification Improvement and Management of Hypertensive Disorders.Reviews in cardiovascular medicine · 2025Review
- Accuracy of the smartphone blood pressure measurement solution OptiBP to track blood pressure changes in pregnant women.Journal of hypertension · 2025Article
- Hypertension in Pregnancy and Postpartum: Current Standards and Opportunities to Improve Care.Circulation · 2025Review
- Hypertension phenotypes and adverse pregnancy outcome-related office and ambulatory blood pressure thresholds during pregnancy: a retrospective cohort study.Hypertension research : official journal of the Japanese Society of Hypertension · 2025Article
- Seasonal variation in home blood pressure during pregnancy and frequency of hypertensive disorders of pregnancy: a multicenter prospective study of home blood pressure measurements in pregnant women using information technology.Hypertension research : official journal of the Japanese Society of Hypertension · 2025Article
- Automated image transcription for perinatal blood pressure monitoring using mobile health technology.PLOS digital health · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
11 authors at 2 institutions in 1 country.
Funding
Abstract
The accurate measurement of blood pressure (BP) in pregnancy is essential to guide medical decision making that affects both mother and fetus. The aim of this systematic review was to determine the accuracy of ambulatory, home, and clinic BP measurement devices in pregnant women. We searched Ovid MEDLINE, The Cochrane Library, EMBASE, CINAHL EBSCO, ClinicalTrials.gov, International Clinical Trials Registry Platform, and dabl from inception through August 3, 2017 for articles that assessed the validity of an upper arm BP measurement device against a mercury sphygmomanometer in pregnant women. Two independent investigators determined eligibility, extracted data, and adjudicated protocol violations. From 1798 potential articles identified, 41, that assessed 28 devices, met the inclusion criteria. Most articles (n=32) followed a standard or modified American National Standards Institute/Association for the Advancement of Medical Instrumentation/International Organization for Standardization, British Hypertension Society, or European Society of Hypertension validation protocol. Several articles described the results of validation studies performed on >1 device (n=7) or in >1 population of pregnant women (n=12), comprising 64 pairwise validity assessments. The device was validated in 61% (32 of 52) of studies which used a standard or modified protocol. Only 34% (11 of 32) of the studies wherein the device was successfully validated were performed without a protocol violation. Given the implications of inaccurate BP measurement in pregnant women, healthcare providers should be aware of and try to use the BP measurement devices which have been properly validated in this population.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.