Evidence map›Paper›PMID 29228956›Full record

ArticleBMC musculoskeletal disorders2017

Analysis of bearing wear, whole blood and synovial fluid metal ion concentrations and histopathological findings in patients with failed ASR hip resurfacings.

Lari Lehtovirta, Aleksi Reito, Jyrki Parkkinen, Harry Hothi, Johann Henckel, Alister Hart, Antti Eskelinen

Open access · goldAbstract read
In one paragraph

Article in BMC musculoskeletal disorders, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
2.0field-weighted citation impact, top 13% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 17 citations in OpenAlex.

  1. Prosthetic Metals: Release, Metabolism and Toxicity.International journal of nanomedicine · 2024
    Review
  2. Review
  3. Semi-quantitative histology confirms that the macrophage is the predominant cell type in metal-on-metal hip tissues.Journal of orthopaedic research : official publication of the Orthopaedic Research Society · 2022
    Article
  4. Analysis of retrieved STRYDE nails.Bone & joint open · 2021
    Article
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 4 institutions in 2 countries.

Lari LehtovirtaFaculty of Medicine, University of Tampere, Tampere, Finland. lehtovirta.lari.a@student.uta.fi.ORCID http://orcid.org/0000-0002-9391-8915
Aleksi ReitoCoxa Hospital for Joint Replacement, Tampere, Finland.
Jyrki ParkkinenFimlab Laboratories Oy, Tampere, Finland.
Harry HothiUniversity College London, London, UK.
Johann HenckelUniversity College London, London, UK.
Alister HartUniversity College London, London, UK.
Antti EskelinenCoxa Hospital for Joint Replacement, Tampere, Finland.
University College London · GBCoxa Hospital · FIFimlab (Finland) · FITampere University · FI

Funding

Pirkanmaa Hospital District (FI), representing government funding 9N044
6 · The paper itself

Abstract

backgroundAdverse Reaction to Metal Debris (ARMD) is still a major reason for revision surgeries in patients with metal-on-metal (MoM) hip replacements. ARMD consists of a wide range of alterations in periprosthetic tissues, most important of which are metallosis, inflammation, pseudotumors and necrosis. Studies investigating histopathological findings and their association to implant wear or indirect measures of wear have yielded inconsistent results. Therefore, we aimed to investigate bearing surface wear volume, whole blood and synovial fluid metal ion concentrations, histopathological findings in periprosthetic tissues and their associations.

methodsSeventy-eight patients with 85 hips revised for ARMD were included in the study. Prior to revision surgery, all patients had whole blood chromium and cobalt ion levels assessed. In revision surgery, a synovial fluid sample was taken and analyzed for chromium and cobalt. Periprosthetic tissue samples were taken and analyzed for histopathological findings. Explanted implants were analyzed for bearing wear volume of both acetabular cup and femoral head components.

resultsVolumetric wear of the failed components was highly variable. The total wear volume of the head and cup had a strong correlation with whole blood chromium and cobalt ion concentrations (Cr: ρ = 0.80, p < 0.001 and Co: ρ = 0.84, p < 0.001) and a bit weaker correlation with fluid chromium and cobalt ion concentrations (Cr: ρ = 0.50, p < 0.01 and Co: ρ = 0.41, p = 0.027). Most tissues displayed only low-to-moderate amounts of macrophages and lymphocytes. Total wear volume correlated with macrophage sheet thickness (ρ = 0.25, p = 0.020) and necrosis (ρ = 0.35, p < 0.01). Whole blood chromium and cobalt ion concentrations had similar correlations. Lymphocyte cuff thickness did not correlate with either total wear volume or whole blood metal ion concentrations, but correlated with the grade of necrosis.

conclusionsBearing wear volume correlated with blood metal ion levels and the degree of necrosis and macrophage infiltration in periprosthetic tissues suggesting a dose-response relationship. Whole blood metal ion levels are a useful tool for clinician to estimate bearing wear and subsequent tissue response.

Indexed as

AcetabulumAgedArthroplasty, Replacement, HipFemaleFemur HeadFollow-Up StudiesHip JointHip ProsthesisHumansInflammationIonsMaleMetal-on-Metal Joint ProsthesesMetalsMiddle AgedNecrosisIonsMetalsAdverse reaction to metal debrisALTRALVALARMDHistopathologyMetal-on-metal hip replacementWear

Identifiers

PMID29228956
PMCPMC5725985
OpenAlexW2773666809

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.