Evidence map›Paper›PMID 29226509›Full record

ArticleJournal of biomedical materials research. Part A2018

Biomimetic electrospun coatings increase the in vivo sensitivity of implantable glucose biosensors.

Krishna Burugapalli, Shavini Wijesuriya, Ning Wang, Wenhui Song

Open access · hybridAbstract read
In one paragraph

Article in Journal of biomedical materials research. Part A, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
1.1field-weighted citation impact, top 26% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed, 32 citations in OpenAlex.

  1. Review
  2. Recent Advances in Electrospinning Techniques for Precise Medicine.Cyborg and bionic systems (Washington, D.C.) · 2024
    Review
  3. Review
  4. Review
  5. Article
  6. Review
  7. Review
  8. Review
  9. Flexible Electronics for MonitoringFrontiers in chemistry · 2020
    Review
  10. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 1 country.

Krishna BurugapalliBiomedical Engineering Theme, Institute for Environment, Health and Societies, Brunel University London, Uxbridge, UB8 3PH, United Kingdom.
Shavini WijesuriyaBiomedical Engineering Theme, Institute for Environment, Health and Societies, Brunel University London, Uxbridge, UB8 3PH, United Kingdom.
Ning WangBiomedical Engineering Theme, Institute for Environment, Health and Societies, Brunel University London, Uxbridge, UB8 3PH, United Kingdom.
Wenhui SongUCL Centre for Nanotechnology and Regenerative Medicine, Division of Surgery and Interventional Science, University College London, London, NW3 2PF, United Kingdom.
Brunel University of London · GBUniversity College London · GB

Funding

Glucose Sensor/Tissue Interactions EngineeringR01EB001640 · NIBIB · UNIVERSITY OF SOUTH FLORIDA · PI MOUSSY, FRANCIS · 2003 to 2007
$2.1M
NIBIB NIH HHS R01 EB001640
6 · The paper itself

Abstract

In vivo tissue responses and functional efficacy of electrospun membranes based on polyurethane (PU) and gelatin (GE) as biomimetic coatings for implantable glucose biosensors was investigated in a rat subcutaneous implantation model. Three electrospun membranes with optimized fiber diameters, pore sizes, and permeability, both single PU and coaxial PU-GE fibers and a solvent cast PU film were implanted in rats to evaluate tissue responses. For functional efficacy testing, four sensor variants coated with the above mentioned electrospun membranes as mass-transport limiting and outermost biomimetic coatings were implanted in rats. The electrospun PU membranes had micron sized pores that were not permeable to host cells when implanted in the body. However, PU-GE coaxial fiber membranes, having similar sized pores, were infiltrated with fibroblasts that deposited collagen in the membrane's pores. Such tissue response prevented the formation of dense fibrous capsule around the sensor coated with the PU-GE coaxial fiber membranes, which helped improve the in vivo sensitivity for at least 3 weeks compared to the traditional sensors in rat subcutaneous tissue. Furthermore, the better in vitro sensor's sensitivity due to electrospun PU as the mass-transport limiting membrane translated to better in vivo sensitivity. Thus, this study showed that electrospun membranes can play an important role in realizing long in vivo sensing lifetime of implantable glucose biosensors. © 2017 The Authors Journal of Biomedical Materials Research Part A Published by Wiley Periodicals, Inc. J Biomed Mater Res Part A: 106A: 1072-1081, 2018.

Indexed as

Prostheses and ImplantsAnimalsBiomimetic MaterialsBiomimeticsBiosensing TechniquesBlood GlucoseCoated Materials, BiocompatibleElectrochemical TechniquesGlucoseRatsSubcutaneous TissueBlood GlucoseCoated Materials, BiocompatibleGlucosecontinuous glucose monitoringelectrospun coaxial fiber membranesimplantable electrochemical sensorin vivo functional efficacytissue reactions

Identifiers

PMID29226509
PMCPMC5826864
OpenAlexW2775073707

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.