Evidence map›Paper›PMID 29224048›Full record

ArticleLasers in medical science2018

Comparison between whole-body and head and neck neurovascular coils for 3-T magnetic resonance proton resonance frequency shift thermography guidance in the head and neck region.

Daniel Thomas Ginat, Gregory J Anthony, Gregory Christoforidis, Aytekin Oto, Leonard Dalag, Steffen Sammet

Abstract readComparative Study
In one paragraph

Article in Lasers in medical science, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.3field-weighted citation impact, top 42% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 2 citations in OpenAlex.

  1. MR Thermography-Guided Head and Neck Lesion Laser Ablation.AJNR. American journal of neuroradiology · 2018
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Daniel Thomas GinatDepartment of Radiology, Pritzker School of Medicine, University of Chicago, 5841 S Maryland Avenue, Chicago, IL, 60637, USA. dtg1@uchicago.edu.
Gregory J AnthonyDepartment of Radiology, Pritzker School of Medicine, University of Chicago, 5841 S Maryland Avenue, Chicago, IL, 60637, USA.
Gregory ChristoforidisDepartment of Radiology, Pritzker School of Medicine, University of Chicago, 5841 S Maryland Avenue, Chicago, IL, 60637, USA.
Aytekin OtoDepartment of Radiology, Pritzker School of Medicine, University of Chicago, 5841 S Maryland Avenue, Chicago, IL, 60637, USA.
Leonard DalagDepartment of Radiology, Pritzker School of Medicine, University of Chicago, 5841 S Maryland Avenue, Chicago, IL, 60637, USA.
Steffen SammetDepartment of Radiology, Pritzker School of Medicine, University of Chicago, 5841 S Maryland Avenue, Chicago, IL, 60637, USA.
University of Chicago · US

Funding

RESEARCH TRAINING IN MEDICAL PHYSICST32EB002103 · NIBIB · UNIVERSITY OF CHICAGO · PI ARMATO, SAMUEL G. · 2003 to 2019
$4.7M
NIBIB NIH HHS T32 EB002103
6 · The paper itself

Abstract

The purpose of this study is to compare the image quality of magnetic resonance (MR) treatment planning images and proton resonance frequency (PRF) shift thermography images and inform coil selection for MR-guided laser ablation of tumors in the head and neck region. Laser ablation was performed on an agar phantom and monitored via MR PRF shift thermography on a 3-T scanner, following acquisition of T1-weighted (T1W) planning images. PRF shift thermography images and T2-weighted (T2W) planning images were also performed in the neck region of five normal human volunteers. Signal-to-noise ratios (SNR) and temperature uncertainty were calculated and compared between scans acquired with the quadrature mode body integrated coil and a head and neck neurovascular coil. T1W planning images of the agar phantom produced SNRs of 4.0 and 12.2 for the quadrature mode body integrated coil and head and neck neurovascular coil, respectively. The SNR of the phantom MR thermography magnitude images obtained using the quadrature mode body integrated coil was 14.4 versus 59.6 using the head and neck coil. The average temperature uncertainty for MR thermography performed on the phantom with the quadrature mode body integrated coil was 1.1 versus 0.3 °C with the head and neck coil. T2W planning images of the neck in five human volunteers produced SNRs of 28.3 and 91.0 for the quadrature mode body integrated coil and head and neck coil, respectively. MR thermography magnitude images of the neck in the volunteers obtained using the quadrature mode body integrated coil had a signal-to-noise ratio of 8.3, while the SNR using the head and neck coil was 16.1. The average temperature uncertainty for MR thermography performed on the volunteers with the body coil was 2.5 versus 1.6 °C with the head and neck neurovascular coil. The quadrature mode body integrated coil provides inferior image quality for both basic treatment planning sequences and MR PRF shift thermography compared with a neurovascular coil, but may nevertheless be adequate for clinical purposes.

Indexed as

ProtonsThermographyHeadHealthy VolunteersHumansMagnetic Resonance ImagingNeckPhantoms, ImagingSignal-To-Noise RatioTemperatureProtonsHead and neckMRI proton resonance frequency shift thermographyPhantomQuadrature body integrated coilSignal-to-noise ratioThermal ablation

Identifiers

PMID29224048
PMCPMC11956765
OpenAlexW2774412632

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.