ArticleMagnetic resonance in medicine2018
Free-breathing whole-heart 3D cine magnetic resonance imaging with prospective respiratory motion compensation.
Article in Magnetic resonance in medicine, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 27 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
27 citing papers in PubMed, 1 synthesis or guideline pooled it.
- Society for Cardiovascular Magnetic Resonance recommendations toward environmentally sustainable cardiovascular magnetic resonance.Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance · 2025Guideline
- Automated whole-heart volumetrics and haemodynamics from 4D flow CMR magnitude images: development and validation of a deep learning model.European heart journal. Imaging methods and practice · 2026Article
- Free-Breathing 3D Whole Heart and Aorta Cine MRI Without Contrast Agent-Comparison to Clinical Standard.Journal of magnetic resonance imaging : JMRI · 2026Article
- EMORe: Motion-Robust 5D MRI Reconstruction via Expectation-Maximization-Guided Binning Correction and Outlier Rejection.IEEE transactions on medical imaging · 2026Article
- Feasibility Study for Dual Phase Free Breathing 3D bSSFP MRA With Preserved Eddy-Current Tolerance With Adaptive k-Space Lengths (PETAL) Acquisition.Magnetic resonance in medicine · 2026Article
- The Use of Ultrasound Imaging in Continuous Blood Vessel Area and Velocity Data Acquisition for Determining the Local Pulse Wave Velocity.Journal of clinical medicine · 2025Review
- Free-running isotropic three-dimensional cine magnetic resonance imaging with deep learning image reconstruction.Pediatric radiology · 2025Article
- Democratizing cardiac imaging with an automated magnetic resonance exam.Research square · 2025Article
- 3D non-contrast whole‑heart coronary MR angiography at 3 T with compressed sensing in elderly patients: Optimization of the acceleration factor.European journal of radiology open · 2025Article
- Ferumoxytol-Enhanced Cardiac Cine MRI Reconstruction Using a Variable-Splitting Spatiotemporal Network.Journal of magnetic resonance imaging : JMRI · 2024Article
- Free-Running Cardiac and Respiratory Motion-Resolved Imaging: A Paradigm Shift for Managing Motion in Cardiac MRI?Diagnostics (Basel, Switzerland) · 2024Review
- Similarity-driven motion-resolved reconstruction for ferumoxytol-enhanced whole-heart MRI in congenital heart disease.PloS one · 2024Article
- Retrospective motion correction through multi-average k-space data elimination (REMAKE) for free-breathing cardiac cine imaging.Magnetic resonance in medicine · 2023Article
- Non-contrast free-breathing whole-heart 3D cine cardiovascular magnetic resonance with a novel 3D radial leaf trajectory.Magnetic resonance imaging · 2022Article
- Ferumoxytol-enhanced 4D multiphase, steady-state imaging with magnetic resonance in congenital heart disease: ventricular volume and function across 2D and 3D software platforms.Quantitative imaging in medicine and surgery · 2022Article
- Reliability of pediatric ventricular function analysis by short-axis "single-cycle-stack-advance" single-shot compressed-sensing cines in minimal breath-hold time.European radiology · 2022Article
- Taking It Personally: 3D Bioprinting a Patient-Specific Cardiac Patch for the Treatment of Heart Failure.Bioengineering (Basel, Switzerland) · 2022Review
- Cardiac phase-resolved late gadolinium enhancement imaging.Frontiers in cardiovascular medicine · 2022Article
- Cardiac MR: From Theory to Practice.Frontiers in cardiovascular medicine · 2022Review
- A completely automated pipeline for 3D reconstruction of human heart from 2D cine magnetic resonance slices.Philosophical transactions. Series A, Mathematical, physical, and engineering sciences · 2021Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
Abstract
purposeTo develop and validate a new prospective respiratory motion compensation algorithm for free-breathing whole-heart 3D cine steady-state free precession (SSFP) imaging.
methodsIn a 3D cine SSFP sequence, 4 excitations per cardiac cycle are re-purposed to prospectively track heart position. Specifically, their 1D image is reconstructed and routed into the scanner's standard diaphragmatic navigator processing system. If all 4 signals are in end-expiration, cine image data from the entire cardiac cycle is accepted for image reconstruction. Prospective validation was carried out in patients (N = 17) by comparing in each a conventional breath-hold 2D cine ventricular short-axis stack and a free-breathing whole-heart 3D cine data set.
resultsAll 3D cine SSFP acquisitions were successful and the mean scan time was 5.9 ± 2.7 min. Left and right ventricular end-diastolic, end-systolic, and stroke volumes by 3D cine SSFP were all larger than those from 2D cine SSFP. This bias was < 6% except for right ventricular end-systolic volume that was 12%. The 3D cine images had a lower ventricular blood-to-myocardium contrast ratio, contrast-to-noise ratio, mass, and subjective quality score.
conclusionThe novel prospective respiratory motion compensation method for 3D cine SSFP imaging was robust and efficient and yielded slightly larger ventricular volumes and lower mass compared to breath-hold 2D cine imaging. Magn Reson Med 80:181-189, 2018. © 2017 International Society for Magnetic Resonance in Medicine.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.