Evidence map›Paper›PMID 29222614›Full record

ArticleMedical & biological engineering & computing2018

A singular K-space model for fast reconstruction of magnetic resonance images from undersampled data.

Jianhua Luo, Zhiying Mou, Binjie Qin, Wanqing Li, Philip Ogunbona, Marc C Robini, Yuemin Zhu

Abstract read
PubMed Publisher
In one paragraph

Article in Medical & biological engineering & computing, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Jianhua LuoSchool of Aeronautics and Astronautics, Shanghai Jiao Tong University, Shanghai, 200240, People's Republic of China.
Zhiying MouChina National Aeronautical Radio Electronics Research Institute, Shanghai, 200233, People's Republic of China.
Binjie QinSchool of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, 200240, People's Republic of China. bjqin@sjtu.edu.cn.ORCID http://orcid.org/0000-0001-7445-1582
Wanqing LiSchool of Computing and Information Technology, University of Wollongong, Wollongong, NSW, 2522, Australia.
Philip OgunbonaSchool of Computing and Information Technology, University of Wollongong, Wollongong, NSW, 2522, Australia.
Marc C RobiniINSA Lyon, CNRS, Inserm, CREATIS UMR 5220, U1206, F-69621, Université Lyon, Lyon, France.
Yuemin ZhuINSA Lyon, CNRS, Inserm, CREATIS UMR 5220, U1206, F-69621, Université Lyon, Lyon, France.

Funding

China Aviation Industry cxy204SHJD22National Natural Science Foundation of China 61271320Region Rhône-Alpes of France CMIRA COOPERA 2013340
6 · The paper itself

Abstract

Reconstructing magnetic resonance images from undersampled k-space data is a challenging problem. This paper introduces a novel method of image reconstruction from undersampled k-space data based on the concept of singularizing operators and a novel singular k-space model. Exploring the sparsity of an image in the k-space, the singular k-space model (SKM) is proposed in terms of the k-space functions of a singularizing operator. The singularizing operator is constructed by combining basic difference operators. An algorithm is developed to reliably estimate the model parameters from undersampled k-space data. The estimated parameters are then used to recover the missing k-space data through the model, subsequently achieving high-quality reconstruction of the image using inverse Fourier transform. Experiments on physical phantom and real brain MR images have shown that the proposed SKM method constantly outperforms the popular total variation (TV) and the classical zero-filling (ZF) methods regardless of the undersampling rates, the noise levels, and the image structures. For the same objective quality of the reconstructed images, the proposed method requires much less k-space data than the TV method. The SKM method is an effective method for fast MRI reconstruction from the undersampled k-space data. Graphical abstract Two Real Images and their sparsified images by singularizing operator.

Indexed as

AlgorithmsImage Processing, Computer-AssistedMagnetic Resonance ImagingModels, TheoreticalElastic ModulusPhantoms, ImagingSignal-To-Noise RatioImage reconstructionMagnetic resonance imaging (MRI)Singular k-space modelTotal variation (TV)Undersampled k-space data

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.