Evidence map›Paper›PMID 29218618›Full record

ArticleEuropean radiology2018

Metal artifact reduction MRI of total ankle arthroplasty implants.

Cesar de Cesar Netto, Lucas F Fonseca, Benjamin Fritz, Steven E Stern, Esther Raithel, Mathias Nittka, Lew C Schon, Jan Fritz

Abstract read
PubMed Publisher
In one paragraph

Article in European radiology, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Review
  2. Advances in Bone Joint Imaging-Metal Artifact Reduction.Diagnostics (Basel, Switzerland) · 2022
    Review
  3. Article
  4. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Cesar de Cesar NettoDepartment of Orthopedic Surgery, MedStar Union Memorial Hospital, Baltimore, MD, USA.
Lucas F FonsecaDepartment of Orthopedic Surgery, MedStar Union Memorial Hospital, Baltimore, MD, USA.
Benjamin FritzDepartment of Radiology, Balgrist University Hospital, Zurich, Switzerland.
Steven E SternBond Business School, Bond University, Gold Coast, QLD, Australia.
Esther RaithelSiemens Healthcare GmbH, Erlangen, Germany.
Mathias NittkaSiemens Healthcare GmbH, Erlangen, Germany.
Lew C SchonDepartment of Orthopedic Surgery, MedStar Union Memorial Hospital, Baltimore, MD, USA.
Jan FritzRussell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, MD, USA. jfritz9@jhmi.edu.ORCID http://orcid.org/0000-0003-4456-3043

Funding

Siemens USA n/a
6 · The paper itself

Abstract

objectivesTo assess high-bandwidth and compressed sensing-(CS)-SEMAC turbo spin echo (TSE) techniques for metal artifact reduction MRI of total ankle arthroplasty (TAA) implants.

methodsFollowing institutional approval and consent, 40 subjects with TAA implants underwent 1.5-T MRI prospectively. Evaluations included bone-implant interfaces, anatomical structures, abnormal findings and differential diagnoses before and after MRI. AUCs of P-P plots were used to determine superiority. Statistical differences were evaluated with McNemar and chi-square tests. P-values ≤ 0.05 were considered significant.

resultsCS-SEMAC TSE was superior to high-bandwidth TSE in showing the bone-implant interfaces (AUC=0.917), periprosthetic bone, tendons and joint capsule (AUC=0.337-0.766), bone marrow oedema (43 % difference, p=0.041), interface osteolysis (63 %, p=0.015), tendinopathy (62 %, p=0.062), periprosthetic fractures (60 %, p=0.250), synovitis (43 %, p=0.250), as well as reader confidence for bone marrow oedema (p=<0.001), fracture (p=0.001), interface osteolysis (p=0.003), synovitis (p=0.027) and tendinopathy (p=0.034). The number of differential diagnoses in symptomatic subjects after the MRI with CS-SEMAC decreased from 3 (1-4) to 1 (1-2) (p<0.001).

conclusionsMRI of TAA implants with CS-SEMAC improves the diagnosis of interface osteolysis, periprosthetic bone marrow oedema, fractures and tendinopathy when compared to high-BW TSE, and has a positive effect on patient management. KEY POINTS: • High-bandwidth TSE and compressed sensing SEMAC improve MRI of ankle arthroplasty implants. • Compressed sensing SEMAC improves bone-implant interfaces, periprosthetic bone, tendons and joint capsule visibility. • Compressed sensing SEMAC improves the diagnosis of osteolysis, tendinopathy, fractures and synovitis. • MRI decreases the number of clinical differential diagnoses of painful ankle arthroplasty implants.

Indexed as

Arthroplasty, Replacement, AnkleArtifactsProstheses and ImplantsAgedAnkle JointFemaleHumansImage EnhancementMagnetic Resonance ImagingMaleMiddle AgedAnkleArthroplastyArtifactsJoint prosthesisMagnetic resonance imaging

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.