Evidence map›Paper›PMID 29218235›Full record

ArticleIEEE International Conference on Robotics and Automation : ICRA : [proceedings]. IEEE International Conference on Robotics and Automation

Experimental Validation of the Pseudo-Rigid-Body Model of the MRI-Actuated Catheter.

Tipakorn Greigarn, Russell Jackson, Taoming Liu, M Cenk Çavuşoğlu

Abstract read
In one paragraph

Article in IEEE International Conference on Robotics and Automation : ICRA : [proceedings]. IEEE International Conference on Robotics and Automation. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed.

  1. Path tracking control of a steerable catheter in transcatheter cardiology interventions.International journal of computer assisted radiology and surgery · 2024
    Article
  2. Article
  3. Article
  4. Analysis of Contact Stability and Contact Safety of a Robotic Intravascular Cardiac Catheter under Blood Flow Disturbances.Proceedings of the ... IEEE/RSJ International Conference on Intelligent Robots and Systems. IEEE/RSJ International Conference on Intelligent Robots and Systems · 2020
    Article
  5. Adaptive Dynamic Control for Magnetically Actuated Medical Robots.IEEE robotics and automation letters · 2019
    Article
  6. Article
  7. Article
  8. State Estimation for MRI-Actuated Catheters via Catadioptric Stereo Camera.Proceedings of the ... IEEE/RSJ International Conference on Intelligent Robots and Systems. IEEE/RSJ International Conference on Intelligent Robots and Systems · 2018
    Article
  9. Contact Stability Analysis of Magnetically-Actuated Robotic Catheter Under Surface Motion.IEEE International Conference on Robotics and Automation : ICRA : [proceedings]. IEEE International Conference on Robotics and Automation
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Tipakorn GreigarnDepartment of Electrical Engineering and Computer Science, Case Western Reserve University, Cleveland, OH.
Russell JacksonDepartment of Electrical Engineering and Computer Science, Case Western Reserve University, Cleveland, OH.
Taoming LiuDepartment of Electrical Engineering and Computer Science, Case Western Reserve University, Cleveland, OH.
M Cenk ÇavuşoğluDepartment of Electrical Engineering and Computer Science, Case Western Reserve University, Cleveland, OH.

Funding

NRI: Small: Magnetic Resonance Imaging Guided Co-Robotic Active Catheter SystemR01EB018108 · NIBIB · CASE WESTERN RESERVE UNIVERSITY · PI CAVUSOGLU, M. CENK · 2013 to 2016
$1.3M
NIBIB NIH HHS R01 EB018108
6 · The paper itself

Abstract

An MRI-actuated catheter is a novel robotic catheter system that utilizes the MRI for both remote steering and visualization for catheter ablation of atrial fibrillation. Planning and control of the catheter requires a sufficiently fast yet accurate model of the catheter. The pseudo-rigid-body (PRB) model offers a reasonable trade-off between speed and accuracy by approximating the continuum catheter as rigid links connected by flexible joints, thus reducing the infinite degrees of freedom of the continuum mechanism to a finite one. In this paper, a PRB model of the MRI-actuated catheter is validated experimentally by comparing the deflections of the PRB model with the deflections of the catheter prototype.

Identifiers

PMID29218235
PMCPMC5713912

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.