Evidence map›Paper›PMID 29216225›Full record

ArticlePloS one2017

Real-time visualization of thrombus formation at the interface between connectors and tubes in medical devices by using optical coherence tomography.

Yuki Matsuhashi, Kei Sameshima, Yoshiki Yamamoto, Mitsuo Umezu, Kiyotaka Iwasaki

Open access · goldAbstract readValidation Study
In one paragraph

Article in PloS one, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
1.2field-weighted citation impact, top 19% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 12 citations in OpenAlex.

  1. Tailored 3D Lattice Microstructures for Enhanced Functionality in Blood-Gas Exchange.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2025
    Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Yuki MatsuhashiDepartment of Integrative Bioscience and Biomedical Engineering, Graduate School of Advanced Science and Engineering, Waseda University, Shinjuku, Tokyo, Japan.
Kei SameshimaDepartment of Integrative Bioscience and Biomedical Engineering, Graduate School of Advanced Science and Engineering, Waseda University, Shinjuku, Tokyo, Japan.
Yoshiki YamamotoDepartment of Modern Mechanical Engineering, Graduate School of Creative Science and Engineering, Waseda University, Shinjuku, Tokyo, Japan.
Mitsuo UmezuDepartment of Integrative Bioscience and Biomedical Engineering, Graduate School of Advanced Science and Engineering, Waseda University, Shinjuku, Tokyo, Japan.
Kiyotaka IwasakiDepartment of Integrative Bioscience and Biomedical Engineering, Graduate School of Advanced Science and Engineering, Waseda University, Shinjuku, Tokyo, Japan.
Waseda University · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundBlood-contacting devices have contributed to improving the treatment of patients. However, thrombus formation at the interface between a connector and tube is still a potential source of thrombus-related complications that induce stroke or myocardial infarction. We aimed to develop a non-blood-contacting real-time method for visualizing thrombus formation, and to experimentally investigate the time-dependent phenomenon of thrombus formation at the interface between a connector and a tube in a medical device. METHODS AND

findingsAn optical coherence tomography device with a center wavelength of 1330 nm was used to visualize thrombus formation during porcine blood circulation for 50 min in a closed 50-mL circulation system isolated from ambient air. The thrombus formation sites at the interface between a tube and connector were visualized. The area of the thrombus formation at the interface between the inlet of the connector and the tube was found to be 0.012 ± 0.011 mm2. Conversely, at the interface between the outlet of the connector and the tube, the area was found to be 0.637 ± 0.306 mm2. Thus, significantly larger amounts of thrombus were formed at the outlet interface (p < 0.01). The thrombus formation area at the outlet interface increased over time. Conversely, the area of thrombus formation showed repeated increasing and decreasing behavior at the inlet interface. Flow visualization with particle image velocimetry showed the presence of a flow separated area in the minimal flow phase at the inlet interface and a large recirculating slow flow region at the outlet interface in the minimal flow phase. These data suggested that the recirculating stagnant flow region contributed to thrombus growth.

conclusionsThe method presented here was effective in quantitatively assessing time-dependent phenomena of thrombus formation at the connector-tube interface. The method may contribute to the assessment of thrombogenicity of a novel design of connector.

Indexed as

AnimalsEquipment and SuppliesSwineThrombosisTomography, Optical Coherence

Identifiers

PMID29216225
PMCPMC5720586
OpenAlexW2774772111

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.