Evidence map›Paper›PMID 29214504›Full record

ArticleEuropean journal of clinical microbiology & infectious diseases : official publication of the European Society of Clinical Microbiology2018

Postmarketing experience with Neutrolin® (taurolidine, heparin, calcium citrate) catheter lock solution in hemodialysis patients.

Bruce E Reidenberg, Christoph Wanner, Bruce Polsky, Mariana Castanheira, Alla Shelip, Dirk Stalleicken, Antony E Pfaffle

Abstract read
In one paragraph

Article in European journal of clinical microbiology & infectious diseases : official publication of the European Society of Clinical Microbiology, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Cluster-Randomized Trial of Devices to Prevent Catheter-Related Bloodstream Infection.Journal of the American Society of Nephrology : JASN · 2018
    Trial
  2. Antibiotics (Basel, Switzerland) · 2026
    Article
  3. Article
  4. Review
  5. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Bruce E ReidenbergDepartment of Pharmacology, Weill Cornell Medicine, 1300 York Ave., New York, NY, 10021, USA. breidenberg@gmail.com.ORCID http://orcid.org/0000-0001-5075-3156
Christoph WannerDivision of Nephrology, University of Wurzburg, Wurzburg, Germany.
Bruce PolskyDepartment of Medicine, NYU Winthrop Hospital, Mineola, NY, USA.
Mariana CastanheiraJMI Laboratories, North Liberty, IA, USA.
Alla ShelipCorMedix, Inc., 400 Connell Drive, Suite 5000, Berkeley Heights, NJ, 07922, USA.
Dirk StalleickenCorMedix Europe GmbH, Karlsruhe, Germany.
Antony E PfaffleCorMedix, Inc., 400 Connell Drive, Suite 5000, Berkeley Heights, NJ, 07922, USA. apfaffle@cormedix.com.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Catheter-related bloodstream infections (CRBSI) are major complications for patients with life-threatening conditions requiring chronic vascular catheterization. The wide range of etiologic microbes and the ongoing development of resistance to antimicrobials with specific mechanisms of action make this an appropriate target for applying a nonspecific antimicrobial therapeutic. Taurolidine hydrolyzes into two antimicrobial moieties, formaldehyde and methylene glycol, which react with microbial surfaces. Neutrolin® (taurolidine, heparin, calcium citrate) was recently introduced in Germany as an antimicrobial catheter lock solution. This postmarketing experience collected data on 201 patients at 20 centers from January 2014 through September 2016. Likely CRBSI was observed in 13 episodes in 47,118 days (0.2759 per 1000 days [0.1468, 0.4718]). Thrombosed catheter was observed in seven catheters in 47,118 days (0.1486 per 1000 days [0.0595, 0.3061]). No adverse drug reactions that led to the discontinuation of Neutrolin® use were reported. Two patients experienced occasional transient dysgeusia. Neutrolin®, when used in conjunction with guideline-based catheter care, showed reduction in the rate of both CRBSI and catheter thrombosis relative to recent historical controls.

Indexed as

Catheter-Related InfectionsCentral Venous CathetersProduct Surveillance, PostmarketingRenal DialysisAnti-Bacterial AgentsCalcium CitrateDrug CombinationsGermanyHeparinHumansTaurineThiadiazinesThrombosisAnti-Bacterial AgentsCalcium CitrateDrug CombinationsHeparinTaurinetaurolidineThiadiazines

Identifiers

PMID29214504
PMCPMC5978892

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.