Evidence map›Paper›PMID 29204861›Full record

ArticleKnee surgery, sports traumatology, arthroscopy : official journal of the ESSKA2018

Kinematically aligned total knee arthroplasty reduces knee adduction moment more than mechanically aligned total knee arthroplasty.

Yasuo Niki, Takeo Nagura, Katsuya Nagai, Shu Kobayashi, Kengo Harato

Abstract read
PubMed Publisher
In one paragraph

Article in Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 53 papers, 4 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
53citing papers in PubMed, 4 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

53 citing papers in PubMed, 4 syntheses or guidelines pooled it.

  1. Pooled it
  2. Pooled it
  3. Pooled it
  4. Similar results with kinematic and mechanical alignment applied in total knee arthroplasty.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2020
    Pooled it
  5. Trial
  6. Trial
  7. Trial
  8. Review
  9. Review
  10. Review
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Are current total knee arthroplasty implants tested and approved for personalised alignment?Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2026
    Article
  17. Review
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Yasuo NikiDepartment of Orthopaedic Surgery, School of Medicine, Keio University, Tokyo, Japan.
Takeo NaguraDepartment of Clinical Biomechanics, School of Medicine, Keio University, 35 Shinanomachi, Shinjuku, Tokyo, 160-8582, Japan. nagura@z8.keio.jp.
Katsuya NagaiDepartment of Orthopaedic Surgery, School of Medicine, Keio University, Tokyo, Japan.
Shu KobayashiDepartment of Orthopaedic Surgery, School of Medicine, Keio University, Tokyo, Japan.
Kengo HaratoDepartment of Orthopaedic Surgery, School of Medicine, Keio University, Tokyo, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeKnee adduction moment (KAM) has been recognized as a good clinical surrogate for medial tibiofemoral joint loading and is associated with implant durability after total knee arthroplasty (TKA). This study aimed to examine the effects of joint line obliquity in kinematically aligned TKA (KA-TKA) on KAM during gait.

methodsThe study enrolled 21 knees from 18 patients who underwent cylindrical axis reference KA-TKA and a matched group of 21 knees from 18 patients who underwent mechanically aligned (MA)-TKA as controls. Gait analyses were performed the day before TKA and at an overall mean of 2.6 years postoperatively. First peak KAM and variables associated with frontal knee kinetics were determined and compared between groups.

resultsIn KA-TKA, the proximal tibia was resected with 3.4° ± 1.5° of varus in relation to the mechanical axis, and the final femorotibial shaft axis was 176.7° ± 3.8° with KA-TKA and 174.4° ± 3.0° with MA-TKA. KAM was significantly smaller with KA-TKA than with MA-TKA (p < 0.032). Regarding variables affecting KAM, significant differences were evident between the two TKAs for knee adduction angle (p = 0.0021), lever arm (p = 0.028), and Δlever arm (p = 0.0001).

conclusionsIn KA-TKA, joint line obliquity reduced peak KAM during gait, despite slight varus limb alignment, and this reduced KAM in KA-TKA can tolerate constitutional varus alignment. In clinical settings, KA-TKA thus represents a promising technical option for patients with large coronal bowing of the shaft carrying a risk of increased KAM after TKA. LEVEL OF EVIDENCE: III.

Indexed as

AgedArthroplasty, Replacement, KneeBiomechanical PhenomenaFemaleGaitGenu VarumHumansKnee JointKnee ProsthesisMaleOsteoarthritis, KneeRange of Motion, ArticularConstitutional varusGait analysisJoint line obliquityKinematically aligned total knee arthroplastyKnee adduction moment

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.