Evidence map›Paper›PMID 29199189›Full record

ArticleJournal of musculoskeletal & neuronal interactions2017

Biomechanical study on different lengths of PFNA fixation for unstable intertrochanteric femoral fractures.

J-B Hong, Y Dan, L Ouyang, Y Liu, L-M Xiong, S Li, X-B Feng, Z-W Shao, C Yan, S H Yang and 1 more

Abstract read
In one paragraph

Article in Journal of musculoskeletal & neuronal interactions, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 15 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
15citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

15 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
  3. Article
  4. Article
  5. Article
  6. [Comparison of effectiveness of long and short proximal femoral nail anti-rotation in treatment of type A2.3 intertrochanteric fracture of femur].Zhongguo xiu fu chong jian wai ke za zhi = Zhongguo xiufu chongjian waike zazhi = Chinese journal of reparative and reconstructive surgery · 2024
    Article
  7. Review
  8. Review
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. [Comparison of proximal femoral nail anti-rotation operation in traction bed supine position and non-traction bed lateral position in treatment of intertrochanteric fracture of femur].Zhongguo xiu fu chong jian wai ke za zhi = Zhongguo xiufu chongjian waike zazhi = Chinese journal of reparative and reconstructive surgery · 2020
    Article
  15. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

J-B HongDepartment of Orthopaedics, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430022, China.
Y Dan
L Ouyang
Y Liu
L-M Xiong
S Li
X-B Feng
Z-W Shao
C Yan
S H Yang
P Liu

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveThe aim of our study was to compare the biomechanical stability of the Proximal Femoral Nail Antirotation (PFNA) (with 200 mm, 240 mm and 280 mm-long main nails) for the management of unstable intertrochanteric femoral fractures.

methodsTronzo-Evans Type IV and V fractures were built by applying a three-dimensional finite element model. Further, PFNA-II with 200 mm, 240 mm and 280 mm-long main nails were applied for fixation. The above model is the creation of 3 researchers designed in order to obtain average values of numerical stress. Von Mises stress distribution and medial and lateral stress peak of the femur and PFNA were compared.

results240 mm and 280 mm PFNA medial stress peak was reduced significantly in comparison to 200 mm PFNA (p⟨0.05). However, there was no difference between 240 mm and 280 mm PFN. Also, no statistical difference was observed with any of 3 lengths in both medial and lateral stress peak for Evans Type IV and V PFNA.

conclusion240 mm and 280 mm PFNA could reduce femur fixation medial stress peak. Further, they were more efficient in comparison to the 200 mm PFNA, and their biomechanical stability was similar to that of the 280 mm nail.

Indexed as

Biomechanical PhenomenaBone NailsAdultFemoral FracturesFinite Element AnalysisFracture Fixation, InternalHumansMale

Identifiers

PMID29199189
PMCPMC5749036

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-SA
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.