The use of needle holders in CTF guided biopsies as a dose reduction tool.
Article in Journal of applied clinical medical physics, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
9 citing papers in PubMed, 1 synthesis or guideline pooled it, 16 citations in OpenAlex.
- Occupational Protection in Interventional Radiology. A Joint Guideline of the Cardiovascular and Interventional Radiological Society of Europe and the Society of Interventional Radiology.Cardiovascular and interventional radiology · 2026Guideline
- Effect of Spectral Filtering and Segmental X-ray Tube Current Switch-Off on Interventionalist's Scatter Exposure during CT Fluoroscopy.Bioengineering (Basel, Switzerland) · 2024Article
- Reducing hand radiation during renal access for percutaneous nephrolithotomy: a comparison of radiation reduction techniques.Urolithiasis · 2024Article
- An X-ray lead screen may be used to reduce an interventional radiologist's radiation exposure during CT-guided procedures.Polish journal of radiology · 2022Article
- Birmingham Intervention Tent Technique (BITT): A Technical Note.The Indian journal of radiology & imaging · 2021Review
- Occupational radiation dose to the lens of the eye of medical staff who assist in diagnostic CT scans.Heliyon · 2021Article
- Radiation dose and image quality of CT fluoroscopy with partial exposure mode.Diagnostic and interventional radiology (Ankara, Turkey) · 2020Article
- Surface adhesive and hand-aided needle-assisted biopsy technique (SAHNA).Skeletal radiology · 2020Article
- Dose to the interventional radiologist in CTF-guided procedures.Radiation and environmental biophysics · 2019Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
11 authors at 3 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeThe purpose of this study was to evaluate the efficacy of needle holders in reducing staff hand exposure during biopsies guided by computed tomography fluoroscopy (CTF), through the analysis of data acquired during a detailed monitoring study, undertaken in parallel with an ongoing optimization process to reduce hand irradiation.
methodsHand monitoring was performed with 11 extremity detectors, two per finger (base and tip) and one on the back of the wrist, for the left (dominant) hand, during two series of biopsies with comparable characteristics. The first series (47 biopsies) were performed with only quick-check method (QC) and occasional side-handle (SH) manipulation of the needle. The second series (63 biopsies) were performed after introducing needle holders (NH) in the course of an optimization process.
resultsChoice of technique (QC, QC + NH, QC + SH) by the interventional radiologist (IR) was related to biopsy difficulty. Measured hand exposure was low (< 1 mSv) for all QC-only procedures, and for most of the QC + NH procedures. Occasional side-handle manipulation still occurred during challenging biopsies, so that 8% of biopsies in the second series accounted for ~70% of total fingertip dose (~90 mSv). The methodology used allowed a detailed insight into the dose reduction achievable with needle holders during real procedures, without the limitations of phantom measurements.
conclusionsNeedle holders proved effective in reducing mean hand exposure during clinical procedures where real-time manipulation was necessary. Occasional side-handle manipulation was found to contribute disproportionately to hand exposure. This highlights the importance of individual hand monitoring during CTF guided procedures.