Evidence map›Paper›PMID 29193606›Full record

ArticleThe international journal of medical robotics + computer assisted surgery : MRCAS2018

Real-time probe tracking using EM-optical sensor for MRI-guided cryoablation.

Wenpeng Gao, Baichuan Jiang, Daniel F Kacher, Barry Fetics, Erez Nevo, Thomas C Lee, Jagadeesan Jayender

Open access · greenAbstract read
In one paragraph

Article in The international journal of medical robotics + computer assisted surgery : MRCAS, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.4field-weighted citation impact, top 38% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 9 citations in OpenAlex.

  1. Kalman filter-based EM-optical sensor fusion for needle deflection estimation.International journal of computer assisted radiology and surgery · 2018
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 2 countries.

Wenpeng GaoSchool of Life Science and Technology, Harbin Institute of Technology, Harbin, China.ORCID http://orcid.org/0000-0001-7771-0084
Baichuan JiangDepartment of Mechanical Engineering, Tianjin University, Tianjin, China.
Daniel F KacherDepartment of Radiology, Brigham and Women's Hospital, Harvard Medical School, Massachusetts, USA.
Barry FeticsRobin Medical Inc., Baltimore, Maryland, USA.
Erez NevoRobin Medical Inc., Baltimore, Maryland, USA.
Thomas C LeeDepartment of Radiology, Brigham and Women's Hospital, Harvard Medical School, Massachusetts, USA.
Jagadeesan JayenderDepartment of Radiology, Brigham and Women's Hospital, Harvard Medical School, Massachusetts, USA.
Brigham and Women's Hospital · USRobin Medical (United States) · US

Funding

Image Guided Therapy Center - Ultrasound-based sensor system for the monitoring of COVID-19 patientsP41EB015898 · NIBIB · BRIGHAM AND WOMEN'S HOSPITAL · PI TEMPANY, CLARE M · 2012 to 2021
$18.9M
IMAGE GUIDED THERAPY CENTERP41RR019703 · NCRR · BRIGHAM AND WOMEN'S HOSPITAL · PI JOLESZ, FERENC A · 2010 to 2011
$8.6M
NCRR NIH HHS P41 RR019703NIBIB NIH HHS P41 EB015898
6 · The paper itself

Abstract

backgroundA method of real-time, accurate probe tracking at the entrance of the MRI bore is developed, which, fused with pre-procedural MR images, will enable clinicians to perform cryoablation efficiently in a large workspace with image guidance.

methodsElectromagnetic (EM) tracking coupled with optical tracking is used to track the probe. EM tracking is achieved with an MRI-safe EM sensor working under the scanner's magnetic field to compensate the line-of-sight issue of optical tracking. Unscented Kalman filter-based probe tracking is developed to smooth the EM sensor measurements when occlusion occurs and to improve the tracking accuracy by fusing the measurements of two sensors.

resultsExperiments with a spine phantom show that the mean targeting errors using the EM sensor alone and using the proposed method are 2.21 mm and 1.80 mm, respectively.

conclusionThe proposed method achieves more accurate probe tracking than using an EM sensor alone at the MRI scanner entrance.

Indexed as

Phantoms, ImagingAlgorithmsCalibrationCryosurgeryElectromagnetic PhenomenaEquipment DesignHumansImage Processing, Computer-AssistedMagnetic Resonance ImagingOptics and PhotonicsProgramming LanguagesReproducibility of ResultsUser-Computer Interfaceelectromagnetic trackingMRI-guided cryoablationoptical trackingprobe trackingunscented Kalman filter

Identifiers

PMID29193606
PMCPMC5903460
OpenAlexW2769048386

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.