Evidence map›Paper›PMID 29188114›Full record

ArticleBiomedical optics express2017

Optical surface plasmon resonance sensor modified by mutant glucose/galactose-binding protein for affinity detection of glucose molecules.

Dachao Li, Jie Su, Jia Yang, Songlin Yu, Jingxin Zhang, Kexin Xu, Haixia Yu

Open access · goldAbstract read
In one paragraph

Article in Biomedical optics express, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.6field-weighted citation impact, top 33% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 23 citations in OpenAlex.

  1. Article
  2. Review
  3. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 1 country.

Dachao LiSchool of Precision Instrument and Opto-Electronics Engineering at Tianjin University, Tianjin 300072, China.
Jie SuSchool of Precision Instrument and Opto-Electronics Engineering at Tianjin University, Tianjin 300072, China.
Jia YangTianjin Institute of Metrological Supervision and Testing, Tianjin 300192, China.
Songlin YuTianjin Institute of Metrological Supervision and Testing, Tianjin 300192, China.
Jingxin ZhangSchool of Precision Instrument and Opto-Electronics Engineering at Tianjin University, Tianjin 300072, China.
Kexin XuSchool of Precision Instrument and Opto-Electronics Engineering at Tianjin University, Tianjin 300072, China.
Haixia YuSchool of Precision Instrument and Opto-Electronics Engineering at Tianjin University, Tianjin 300072, China.
Tianjin University · CNTianjin Institute of Metrological Supervision Testing · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Transdermal extraction of interstitial fluid (ISF) offers an attractive method for minimally invasive blood glucose monitoring. However, only a minute volume of ISF could be transdermally extracted, which is required to be diluted to form a manipulable volume of fluid for easy collection, transportation, and glucose detection. Therefore, a high-resolution glucose detection method is required for detecting glucose concentration in diluted ISF. In this paper, an optical surface plasmon resonance (SPR) sensor modified by the glucose/galactose-binding (GGB) protein which has good affinity to glucose molecules was presented for specific and sensitive glucose detection. The GGB protein was mutated at different sites for thiol coupling with the SPR surface and adjusting the affinity between glucose molecules and GGB protein. And the immobilization process of the GGB protein onto the surface of SPR sensor was optimized. Then, the stability of the SPR sensor modified with GGB protein was tested immediately and two weeks after immobilization. The coefficient of variation for glucose concentration measurement was less than 4.5%. By further mutation of the GGB protein at the A213S and L238S sites, the measurement range of the SPR sensor was adjusted to 0.1-100 mg/dL, which matches the glucose concentration range of 5-10 times diluted ISF (3-100 mg/dL). These results suggest that the SPR biosensor immobilized with GGB protein has the potential for continuous glucose monitoring by integrating into the microfluidic ISF extraction chip.

Indexed as

(040.1880) Detection(130.6010) Sensors(170.1420) Biology(240.6680) Surface plasmons

Identifiers

PMID29188114
PMCPMC5695964
OpenAlexW2765709745

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.