Evidence map›Paper›PMID 29185003›Full record

ArticleKnee surgery, sports traumatology, arthroscopy : official journal of the ESSKA2018

Ultrasound measurements of Achilles tendon length using skin markings are more reliable than extended-field-of-view imaging.

Espen Femmo Brouwer, Ståle Bergman Myhrvold, Jūratė Šaltytė Benth, Sigurd Erik Hoelsbrekken

Abstract read
PubMed Publisher
In one paragraph

Article in Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Trial
  2. Reliability of the Copenhagen Achilles length measure (CALM) on patients with an Achilles tendon rupture.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2020
    Trial
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Espen Femmo BrouwerDepartment of Orthopaedic Surgery, Akershus University Hospital, Lørenskog, Norway.
Ståle Bergman MyhrvoldDepartment of Orthopaedic Surgery, Akershus University Hospital, Lørenskog, Norway.
Jūratė Šaltytė BenthInstitute of Clinical Medicine, Campus Ahus, University of Oslo, Oslo, Norway.
Sigurd Erik HoelsbrekkenDepartment of Orthopaedic and Rheumatic Surgery, Kongsvinger Hospital, Kongsvinger, Norway. s.e.hoelsbrekken@medisin.uio.no.

Funding

Akershus University Hospital Strat 009
6 · The paper itself

Abstract

purposeElongation of the Achilles tendon has been associated with poorer function in patients treated for ruptures. This has led to the development of various ultrasound-based measurements, and the purpose of the present study was to compare the reliability of three ultrasound-based measuring procedures.

methodsTwenty healthy individuals (40 tendons) were assessed by two testers at two occasions, 12 weeks apart. The tendon length was measured from the calcaneal insertion to the mid-sagittal muscle tendon junction (MTJ) using skin markings or extended-field-of-view (EFOV) imaging, or from the calcaneal insertion to the distal medial MTJ using skin markings. Test-retest and inter-tester reliability as well as side-to-side length differences were assessed for all three procedures.

resultsTest-retest intraclass correlation coefficients (ICCs) for measurements from the mid-sagittal MTJ using EFOV imaging and skin markings, and from the distal medial MTJ using skin markings were 0.83, 0.90 and 0.96 for tester 1 and 0.87, 0.91 and 0.96 for tester 2, respectively. The corresponding inter-tester ICCs were 0.85, 0.91 and 0.96. Side-to-side lengths were significantly different for measurements from the mid-sagittal MTJ and the distal medial MTJ using skin markings, with mean differences of 0.3 and 0.4 cm, respectively.

conclusionsTest-retest and inter-tester ICCs were excellent for all three measuring procedures, however, the use of skin markings provided consistently better agreement and reliability compared to EFOV images. The best agreement and highest ICCs were achieved for measurements from the distal medial MTJ, but side-to-side length differences warrant caution when contralateral measurements are used to evaluate tendon elongation. LEVEL OF EVIDENCE: III.

Indexed as

Achilles TendonAdultBody Weights and MeasuresCalcaneusFemaleHealthy VolunteersHumansMaleReproducibility of ResultsRuptureSkinUltrasonographyAchilles tendon lengthAchilles tendon ruptureExtended-field-of-view imagingReliabilityTendon elongationUltrasound

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.