Evidence map›Paper›PMID 29182678›Full record

ArticlePloS one2017

Diagnostic performance of point-of-care and central laboratory cardiac troponin assays in an emergency department.

Petra Wilke, Annette Masuch, Oliver Fahron, Stephanie Zylla, Tobias Leipold, Astrid Petersmann

Open access · goldAbstract read
In one paragraph

Article in PloS one, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
1.1field-weighted citation impact, top 20% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 15 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. An investigation of range of motion preservation in fusionless anterior double screw and cord constructs for scoliosis correction.European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2023
    Article
  6. Article
  7. Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

Petra WilkeCentral Emergency Department, Klinikum Frankfurt (Oder) GmbH, Rhön AG, Frankfurt (Oder), Germany.
Annette MasuchInstitute of Clinical Chemistry and Laboratory Medicine, University Medicine Greifswald, Greifswald, Germany.ORCID http://orcid.org/0000-0002-8168-5042
Oliver FahronCentral Emergency Department, Klinikum Frankfurt (Oder) GmbH, Rhön AG, Frankfurt (Oder), Germany.
Stephanie ZyllaInstitute of Clinical Chemistry and Laboratory Medicine, University Medicine Greifswald, Greifswald, Germany.
Tobias LeipoldClinPath GmbH, Berlin, Germany.
Astrid PetersmannInstitute of Clinical Chemistry and Laboratory Medicine, University Medicine Greifswald, Greifswald, Germany.
Universitätsmedizin Greifswald · DEKlinikum Frankfurt Höchst · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Early diagnosis of myocardial infarction (MI) with cardiac troponin (cTn) assays at the point-of-care (POC) is suggested to shorten turn-around-time in the emergency department (ED). The present study aimed at comparing the diagnostic performance of two POC cTn assays with that of a central laboratory high-sensitivity (hs) method, under routine ED conditions. In 2,163 non-selected ED patients suspected for MI, the diagnostic performance of the POC troponin I (TnI), troponin T (TnT), and hs-TnT assay for the prediction of MI was evaluated based on receiver operating characteristic (ROC) analyses and compared with the performance based on the manufacturers' cut-offs. Due to an observed association between renal function as determined by estimated glomerular filtration rate (eGFR) and cTn concentrations, all analyses were stratified by renal function. In patients with normal renal function (eGFR > 60 mL/min/1.73m2), POC and hs assays showed a comparable diagnostic performance as quantified by the area under the ROC curve (AUC) of about 0.88. The ROC-derived optimal cut-off (OCO) levels for the different cTn assays clearly changed with decreasing kidney function. Impaired kidney function required OCO to be three to five times higher to achieve a comparable performance. Particularly cTnT concentrations were strongly associated with renal function. The three cTn assays demonstrated equivalent diagnostic performance in ED-patients admitted with suspected ACS in relation to the release diagnosis, supporting the use of POC testing in this setting. The present results implicate that application of eGFR-specific OCOs may decrease false-positives among patients with impaired renal function. Providing individual cut-offs depending on patients' eGFR might be an appropriate add-on tool to improve specificity in the diagnosis of MI.

Indexed as

Emergency Service, HospitalPoint-of-Care SystemsCase-Control StudiesFemaleHumansLaboratories, HospitalMaleMiddle AgedMyocardial InfarctionSensitivity and SpecificityTroponin ITroponin TTroponin ITroponin T

Identifiers

PMID29182678
PMCPMC5705122
OpenAlexW2768787935

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.