Evidence map›Paper›PMID 29180918›Full record

ArticleBiochemia medica2017

Analytical evaluation of a fully automated immunoassay for faecal calprotectin in a paediatric setting.

Britta Noebauer, Lejla Ramic, Andrea Konstantin, Christina Zachbauer, Elisa Einwallner

Open access · diamondAbstract read
In one paragraph

Article in Biochemia medica, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
1.0field-weighted citation impact, top 21% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 9 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Britta NoebauerDepartment of Laboratory Medicine, Medical University of Vienna, Vienna, Austria.
Lejla RamicDepartment of Laboratory Medicine, Medical University of Vienna, Vienna, Austria.
Andrea KonstantinDepartment of Laboratory Medicine, Medical University of Vienna, Vienna, Austria.
Christina ZachbauerDepartment of Pediatrics and Adolescent Medicine, Medical University of Vienna, Vienna, Austria.
Elisa EinwallnerDepartment of Laboratory Medicine, Medical University of Vienna, Vienna, Austria.
Medical University of Vienna · AT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionFaecal calprotectin (FC) is a routinely used marker for identifying and monitoring children with inflammatory bowel disease (IBD). This non-invasive test is useful for screening children with gastrointestinal symptoms to avoid unnecessary invasive procedures. In this study, we validated for the first time the performance of a fully automated particle-enhanced turbidimetric immunoassay (PETIA) on the VITROS® 5600 analyzer for measurement of FC in symptomatic children and adolescents. MATERIALS AND

methodsFor performance validation of the PETIA (fCAL® turbo, Bühlmann Laboratories, Switzerland) on the VITROS® 5600 analyzer (Ortho Clinical Diagnostics, USA) limit of quantitation (LoQ), linearity, precision data and calibration curve stability were defined. Additionally, 95 faecal samples were measured using the PETIA, an enzyme-linked immunosorbent assay (ELISA; fCAL®, Bühlmann Laboratories, Switzerland) and a semi-quantitative lateral flow assay (Quantum Blue Reader®, Bühlmann Laboratories, Switzerland) for agreement evaluation.

resultsThe LoQ for calprotectin using PETIA on the VITROS® 5600 analyzer was 21 µg/g. The linearity range was 20 - 2100 µg/g and the precision study showed a total coefficient of variation (CV) between 2.3% and 8.9%. The calibration curve was stable for 4 weeks. Using the clinical samples quantifiable by PETIA, ELISA and the semi-quantitative lateral flow assay, Passing-Bablok regression analysis and Bland-Altman plots showed good agreement.

conclusionsDue to good performance characteristics and agreement with established methods, the fully automated PETIA on the routine chemistry analyzer VITROS® 5600 is a new analytical option for the rapid determination of FC.

Indexed as

Enzyme-Linked Immunosorbent AssayAdolescentAutomationCalibrationChildChild, PreschoolFecesFemaleHumansInfantInflammatory Bowel DiseasesLeukocyte L1 Antigen ComplexLimit of DetectionMaleReproducibility of ResultsLeukocyte L1 Antigen Complexcalprotectinfaecesinflammatory bowel diseaseparticle-enhanced turbidimetric immunoassay (PETIA)

Identifiers

PMID29180918
PMCPMC5696752
OpenAlexW2764198338

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked