ArticleJournal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance2017
3D whole-heart phase sensitive inversion recovery CMR for simultaneous black-blood late gadolinium enhancement and bright-blood coronary CMR angiography.
Article in Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 21 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
21 citing papers in PubMed, 42 citations in OpenAlex.
- Simultaneous Multi-Slice Acceleration for Free-Breathing Motion Corrected Late Gadolinium Enhancement Imaging.Magnetic resonance in medicine · 2026Article
- Rapid Visualization of Valves and Myocardium Using Volume Rendering of 3D Cardiac MRI, 4D Cine, and 4D Flow Images.Radiology. Cardiothoracic imaging · 2026Article
- Reslice3Dto2D: Introduction of a software tool to reformat 3D volumes into reference 2D slices in cardiovascular magnetic resonance imaging.BMC research notes · 2024Article
- MRI in the Evaluation of Cryptogenic Stroke and Embolic Stroke of Undetermined Source.Radiology · 2024Review
- Compressed SENSE accelerated 3D single-breath-hold late gadolinium enhancement cardiovascular magnetic resonance with isotropic resolution: clinical evaluation.Frontiers in cardiovascular medicine · 2023Article
- Use of a new non-contrast-enhanced BOOST cardiac MR sequence before electrical cardioversion or ablation of atrial fibrillation-a pilot study.Frontiers in cardiovascular medicine · 2023Article
- Current Concepts and Future Applications of Non-Invasive Functional and Anatomical Evaluation of Coronary Artery Disease.Life (Basel, Switzerland) · 2022Review
- Whole-Heart High-Resolution Late Gadolinium Enhancement: Techniques and Clinical Applications.Journal of magnetic resonance imaging : JMRI · 2022Review
- Cardiac MR: From Theory to Practice.Frontiers in cardiovascular medicine · 2022Review
- 3D whole-heart grey-blood late gadolinium enhancement cardiovascular magnetic resonance imaging.Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance · 2021Article
- Late Gadolinium Enhancement Cardiovascular Magnetic Resonance Assessment of Substrate for Ventricular Tachycardia With Hemodynamic Compromise.Frontiers in cardiovascular medicine · 2021Article
- Accelerated high-resolution free-breathing 3D whole-heart TJournal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance · 2020Article
- Motion-corrected 3D whole-heart water-fat high-resolution late gadolinium enhancement cardiovascular magnetic resonance imaging.Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance · 2020Article
- Journal of Cardiovascular Magnetic Resonance: 2017/2018 in review.Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance · 2019Review
- Respiratory- and cardiac motion-corrected simultaneous whole-heart PET and dual phase coronary MR angiography.Magnetic resonance in medicine · 2019Article
- Non-contrast enhanced simultaneous 3D whole-heart bright-blood pulmonary veins visualization and black-blood quantification of atrial wall thickness.Magnetic resonance in medicine · 2019Article
- Five-minute whole-heart coronary MRA with sub-millimeter isotropic resolution, 100% respiratory scan efficiency, and 3D-PROST reconstruction.Magnetic resonance in medicine · 2019Article
- Journal of Cardiovascular Magnetic Resonance 2017.Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance · 2018Review
- Article
- Motion-corrected whole-heart PET-MR for the simultaneous visualisation of coronary artery integrity and myocardial viability: an initial clinical validation.European journal of nuclear medicine and molecular imaging · 2018Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors at 1 institution in 2 countries.
Funding
Abstract
backgroundPhase sensitive inversion recovery (PSIR) applied to late gadolinium enhancement (LGE) imaging is widely used in clinical practice. However, conventional 2D PSIR LGE sequences provide sub-optimal contrast between scar tissue and blood pool, rendering the detection of subendocardial infarcts and scar segmentation challenging. Furthermore, the acquisition of a low flip angle reference image doubles the acquisition time without providing any additional diagnostic information. The purpose of this study was to develop and test a novel 3D whole-heart PSIR-like framework, named BOOST, enabling simultaneous black-blood LGE assessment and bright-blood visualization of cardiac anatomy.
methodsThe proposed approach alternates the acquisition of a 3D volume preceded by a T
resultsDatasets from 12 patients were quantitatively analysed. The black-blood PSIR BOOST dataset provided statistically improved contrast to noise ratio (CNR) between blood and scar when compared to a clinical 2D PSIR sequence (15.8 ± 3.3 and 4.1 ± 5.6, respectively). Overall agreement in LGE depiction was found between 3D black-blood PSIR BOOST and clinical 2D PSIR acquisitions, with 11/12 PSIR BOOST datasets considered diagnostic. The bright-blood T
conclusionsThe feasibility of BOOST for simultaneous black-blood LGE assessment and bright-blood coronary angiography was successfully tested in patients with cardiovascular disease. The framework enables free-breathing multi-contrast whole-heart acquisitions with 100% scan efficiency and predictable scan time. Complementary information on 3D LGE and heart anatomy are obtained reducing examination time.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.