Evidence map›Paper›PMID 29175829›Full record

Observational studyJournal of neurointerventional surgery2018

Safety and effectiveness of the Low Profile Visualized Intraluminal Support (LVIS and LVIS Jr) devices in the endovascular treatment of intracranial aneurysms: results of the TRAIL multicenter observational study.

Christina Iosif, Michel Piotin, Suzana Saleme, Xavier Barreau, Jacques Sedat, Yves Chau, Nader Sourour, Mohamed Aggour, Herve Brunel, Alain Bonafe and 7 more

Open access · hybridAbstract readMulticenter StudyObservational Study
In one paragraph

Observational study in Journal of neurointerventional surgery, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 35 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
35citing papers in PubMed, 1 pooled it
5.6field-weighted citation impact, top 4% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

35 citing papers in PubMed, 1 synthesis or guideline pooled it, 61 citations in OpenAlex.

  1. Pooled it
  2. Trial
  3. Trial
  4. Review
  5. Article
  6. LVIS EVO stent-through-balloon after hydrocoil embolization of intracranial aneurysms: One-year results.Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2024
    Observational
  7. Article
  8. Article
  9. Article
  10. Observational
  11. Long term safety and effectiveness of LVIS Jr for treatment of intracranial aneurysms- a Canadian Multicenter registry.Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2023
    Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Article
  17. Article
  18. Observational
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

17 authors at 10 institutions in 2 countries.

Christina IosifDepartment of Interventional Neuroradiology, CHU-Limoges Dupuytren University Hospital, Limoges, France.
Michel PiotinDepartment of Interventional Neuroradiology, Foundation Rothschild Hospital, Limoges, France.ORCID http://orcid.org/0000-0002-1354-4328
Suzana SalemeDepartment of Interventional Neuroradiology, CHU-Limoges Dupuytren University Hospital, Limoges, France.
Xavier BarreauDepartment of Interventional Neuroradiology, CHU Pellegrin, Paris, France.ORCID http://orcid.org/0000-0002-4932-1484
Jacques SedatDepartment of Interventional Neuroradiology, Hôpital Saint-Roch, Nice, France.
Yves ChauDepartment of Interventional Neuroradiology, Hôpital Saint-Roch, Nice, France.
Nader SourourDepartment of Interventional Neuroradiology, La Pitié-Salpétrière, Paris, France.
Mohamed AggourDepartment of Interventional Neuroradiology, Hôpital Bellevue, Saint-Etienne, France.
Herve BrunelDepartment of Interventional Neuroradiology, Hôpital de la Timone, Marseille, France.
Alain BonafeDepartment of Interventional Neuroradiology, Hôpital Gui de Chauliac, Montpellier, France.
Paolo MachiDepartment of Interventional Neuroradiology, Hôpital Gui de Chauliac, Montpellier, France.
Carlos RiquelmeDepartment of Interventional Neuroradiology, Hôpital Gui de Chauliac, Montpellier, France.ORCID http://orcid.org/0000-0002-5696-5368
Vincent CostalatDepartment of Interventional Neuroradiology, Hôpital Gui de Chauliac, Montpellier, France.
Laurent PierotDepartment of Interventional Neuroradiology, Hôpital Maison Blanche, Reims, France.
Raphael BlancDepartment of Interventional Neuroradiology, Foundation Rothschild Hospital, Limoges, France.
Charbel MounayerDepartment of Interventional Neuroradiology, CHU-Limoges Dupuytren University Hospital, Limoges, France.
TRAIL Investigators
Centre Hospitalier Universitaire de Limoges · FRHôpital Gui de Chauliac · FRFondation de Rothschild · FRHôpital Saint Roch · FRCentre Hospitalier Universitaire de Bordeaux · FRCentre Hospitalier Universitaire de Reims · FRCentre Hospitalier Universitaire de Saint-Étienne · FRHôpital de la Timone · FRSorbonne Université · FRUniversité de Montpellier · FR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

background and purposeTo evaluate the safety and effectiveness of the low-profile braided intracranial stents called the Low Profile Visualized Intraluminal Support (LVIS) devices for stent-assisted coil embolization of wide-necked intracranial aneurysms. MATERIALS AND

methodsThis was a prospective, multicenter, observational study of unruptured and ruptured intracranial aneurysms treated with the LVIS devices. Imaging and clinical data were independently analyzed respectively by CoreLab and Clinical Event Committee. Primary endpoints were clinical safety, effectiveness, and angiographic stability of the results at 6 and 18 months.

resultsTen centers participated in the study; 102 patients were included and 90 patients (42.2% men, 57.8% women) were eventually analyzed, among which 27 (30.0%) had multiple aneurysms. Twenty-three (25.6%) were ruptured aneurysms, four of which (4.4%) were treated in the acute phase. One aneurysm was treated per patient; 92 LVIS and LVIS Jr devices were placed overall. The total aneurysm occlusion rate was 91.0% on immediate post-procedure angiograms, which remained unchanged at 6-month follow-up and was 92.4% at 18-month follow-up. One patient (1.1%) underwent retreatment between 6 and 18 months of follow-up. A modified Rankin score of 0 was documented for most cases immediately after the procedure (86.7%) and at 6-month (86.8%) and 18-month (83.3%) follow-up. The overall permanent morbidity rate at 18 months was 5.6% and the overall rate of events with sequelae related to the stent was 2.2%. The 18-month procedure-related mortality rate was 3.3%. No patient was deemed to require retreatment at 18-month follow-up.

conclusionThe LVIS/LVIS Jr endovascular devices are safe and effective in the treatment of ruptured and unruptured intracranial aneurysms, with acceptable complication rates, very high immediate total occlusion rates, and stable angiographic results.

Indexed as

StentsAdultAgedAneurysm, RupturedBlood Vessel ProsthesisCerebral AngiographyEndovascular ProceduresFemaleFollow-Up StudiesHumansIntracranial AneurysmMaleMiddle AgedProspective StudiesRetreatmentTreatment Outcomeaneurysmstent

Identifiers

PMID29175829
PMCPMC6031274
OpenAlexW2770830624

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.