ArticleJournal of biomechanics2018
Effects of annular contraction on anterior leaflet strain using an in vitro simulator with a dynamically contracting mitral annulus.
Article in Journal of biomechanics, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
4 citing papers in PubMed.
- Transcatheter measurement of mitral valve coaptation pressure: A proof-of-concept study using animal models.Bioengineering & translational medicine · 2026Article
- A Single-opening&closing Valve Tester for Direct Measurement of Closing Volume of the Heart Valve.Cardiovascular engineering and technology · 2022Article
- Heart Valve Biomechanics: The Frontiers of Modeling Modalities and the Expansive Capabilities ofFrontiers in cardiovascular medicine · 2021Review
- Comparative transcriptomic profiling of myxomatous mitral valve disease in the cavalier King Charles spaniel.BMC veterinary research · 2020Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
Abstract
Using in vitro models, the mechanics as well as surgical techniques for mitral valves (MV) and MV devices can be studied in a more controlled environment with minimal monetary investment and risk. However, these current models rely on certain simplifications, one being that the MV has a static, rigid annulus. In order to study more complex issues of imaging diagnostics and implanted device function, it would be more advantageous to verify their use for a dynamic environment in a dynamic simulator. This study provides the novel design and development of a dynamically contracting annulus (DCA) within an in vitro simulator, and its subsequent use to study MV biomechanics. Experiments were performed to study the ability of the DCA to reproduce the MV leaflet mechanics in vitro, as seen in vivo, as well as investigate how rigid annuloplasties affect MV leaflet mechanics. Experiments used healthy, excised MVs and normal hemodynamics; contractile waveforms were derived from human in vivo data. Stereophotogrammetry and echocardiography were used to measure anterior leaflet strain and the change in MV geometry. In pursuit of the first in vitro MV simulator that more completely represents the dynamic motion of the full valvular apparatus, this study demonstrated the successful operation of a dynamically contracting mitral annulus. It was seen that the diseased contractile state increased anterior leaflet strain compared to the healthy contractile state. In addition, it was also shown in vitro that simulated rigid annuloplasty increased mitral anterior leaflet strain compared to a healthy contraction.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.