Evidence map›Paper›PMID 29168794›Full record

ArticleMaterials (Basel, Switzerland)2017

In Vitro Evaluation of PCL and P(3HB) as Coating Materials for Selective Laser Melted Porous Titanium Implants.

Michael Grau, Julia Matena, Michael Teske, Svea Petersen, Pooyan Aliuos, Laura Roland, Niels Grabow, Hugo Murua Escobar, Nils-Claudius Gellrich, Heinz Haferkamp and 1 more

Abstract read
In one paragraph

Article in Materials (Basel, Switzerland), 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Review
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Michael GrauSmall Animal Clinic, University of Veterinary Medicine Hannover, Foundation, D-30559 Hannover, Germany. michael.grau@tiho-hannover.de.
Julia MatenaSmall Animal Clinic, University of Veterinary Medicine Hannover, Foundation, D-30559 Hannover, Germany. julia.matena@gmx.de.
Michael TeskeInstitute for Biomedical Engineering, Rostock University Medical Center, D-18119 Rostock, Germany. michael.teske@uni-rostock.de.
Svea PetersenFaculty of Engineering and Computer Science, University of Applied Sciences, D-49076 Osnabrueck, Germany. s.petersen@hs-osnabrueck.de.
Pooyan AliuosDepartment of Otorhinolaryngology, Head and Neck Surgery, Hannover Medical School, D-30625 Hannover, Germany. paliuos@yahoo.com.
Laura RolandSmall Animal Clinic, University of Veterinary Medicine Hannover, Foundation, D-30559 Hannover, Germany. laura.roland@yahoo.de.
Niels GrabowInstitute for Biomedical Engineering, Rostock University Medical Center, D-18119 Rostock, Germany. niels.grabow@uni-rostock.de.
Hugo Murua EscobarSmall Animal Clinic, University of Veterinary Medicine Hannover, Foundation, D-30559 Hannover, Germany. hugo.murua.escobar@med.uni-rostock.de.
Nils-Claudius GellrichClinic for Cranio-Maxillo-Facial Surgery, Hannover Medical School, D-30625 Hannover, Germany. gellrich.nils-claudius@mh-hannover.de.
Heinz HaferkampInstitut fuer Werkstoffkunde, Leibniz Universitaet Hannover, D-30823 Garbsen, Germany. haferkamp@iw.uni-hannover.de.
Ingo NolteSmall Animal Clinic, University of Veterinary Medicine Hannover, Foundation, D-30559 Hannover, Germany. ingo.nolte@tiho-hannover.de.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Titanium is widely used as a bone implant material due to its biocompatibility and high resilience. Since its Young's modulus differs from bone tissue, the resulting "stress shielding" could lead to scaffold loosening. However, by using a scaffold-shaped geometry, the Young's modulus can be adjusted. Also, a porous geometry enables vascularisation and bone ingrowth inside the implant itself. Additionally, growth factors can improve these effects. In order to create a deposit and release system for these factors, the titanium scaffolds could be coated with degradable polymers. Therefore, in the present study, synthetic poly-ε-caprolactone (PCL) and the biopolymer poly(3-hydroxybutyrate) (P(3HB)) were tested for coating efficiency, cell adhesion, and biocompatibility to find a suitable coating material. The underlying scaffold was created from titanium by Selective Laser Melting (SLM) and coated with PCL or P(3HB) via dip coating. To test the biocompatibility, Live Cell Imaging (LCI) as well as vitality and proliferation assays were performed. In addition, cell adhesion forces were detected via Single Cell Force Spectroscopy, while the coating efficiency was observed using environmental scanning electron microscopy (ESEM) and energy-dispersive X-ray (EDX) analyses. Regarding the coating efficiency, PCL showed higher values in comparison to P(3HB). Vitality assays revealed decent vitality values for both polymers, while values for PCL were significantly lower than those for blank titanium. No significant differences could be observed between PCL and P(3HB) in proliferation and cell adhesion studies. Although LCI observations revealed decreasing values in cell number and populated area over time on both polymer-coated scaffolds, these outcomes could be explained by the possibility of coating diluent residues accumulating in the culture medium. Overall, both polymers fulfill the requirements regarding biocompatibility. Nonetheless, since only PCL coating ensured the maintenance of the porous implant structure, it is preferable to be used as a coating material for creating a deposit and release system for growth factors.

Indexed as

osteoblastpoly(3-hydroxybutyrate)polycaprolactonetitanium scaffold

Identifiers

PMID29168794
PMCPMC5744279

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked