ArticleBone & joint research2017
Computational study on the effect of malalignment of the tibial component on the biomechanics of total knee arthroplasty: A Finite Element Analysis.
Article in Bone & joint research, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 19 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
19 citing papers in PubMed, 1 synthesis or guideline pooled it.
- Do image-based robotic TKR systems improve radiological or clinical outcomes compared to image-free systems? A systematic review and meta-analysis.Journal of robotic surgery · 2025Pooled it
- Knee medial tightness after total knee arthroplasty is associated with superior clinical outcomes in Chinese patients: a retrospective cohort study.Journal of orthopaedic surgery and research · 2026Article
- Does surgeon handedness affect the outcomes after primary total knee arthroplasty? A retrospective cohort study.World journal of orthopedics · 2026Article
- Accuracy and learning curve of imageless robotic-assisted total knee arthroplasty.Journal of orthopaedics · 2025Article
- Comprehensive Impact of Multiplanar Malalignment on Prosthetic Mechanics Under Gait Loading After Total Knee Arthroplasty-A Finite Element Analysis.Orthopaedic surgery · 2025Article
- The Effects of Biomechanical Loading on the Tibial Insert After Primary Total Knee Arthroplasty: A Systematic Review.Journal of clinical medicine · 2025Review
- Robotic-Assisted Total Knee Arthroplasty in Obese Patients.Arthroplasty today · 2024Article
- Mechanical alignment tolerance of a cruciate-retaining knee prosthesis under gait loading-A finite element analysis.Frontiers in bioengineering and biotechnology · 2023Article
- Computational wear of knee implant polyethylene insert surface under continuous dynamic loading and posterior tibial slope variation based on cadaver experiments with comparative verification.BMC musculoskeletal disorders · 2022Article
- Biomechanical Effect of Coronal Alignment and Ligament Laxity in Total Knee Arthroplasty: A Simulation Study.Frontiers in bioengineering and biotechnology · 2022Article
- The current state of robotics in total knee arthroplasty.EFORT open reviews · 2021Review
- The tibial cut in total knee arthroplasty influences the varus alignment, the femoral roll-back and the tibiofemoral rotation in patients with constitutional varus.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2021Article
- Patient Demographics and Anthropometric Measurements Predict Tibial and Femoral Component Sizing in Total Knee Arthroplasty.Arthroplasty today · 2020Article
- Effect of material selection on tibial post stresses in posterior-stabilized knee prosthesis.Bone & joint research · 2020Article
- Robotic-assisted unicompartmental knee arthroplasty has a greater early functional outcome when compared to manual total knee arthroplasty for isolated medial compartment arthritis.Bone & joint research · 2020Article
- Finite-element analysis of the proximal tibial sclerotic bone and different alignment in total knee arthroplasty.BMC musculoskeletal disorders · 2019Article
- The evolution of patellofemoral prosthetic design in total knee arthroplasty: how far have we come?EFORT open reviews · 2019Review
- Knee biomechanics: Will we ever know the truth?Bone & joint research · 2018Article
- Loading on Attune® fixed-bearing cruciate-substituting total knee implant in knee malalignment during activities of daily living: A finite element analysis.Journal of orthopaedicsArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
objectivesMalalignment of the tibial component could influence the long-term survival of a total knee arthroplasty (TKA). The object of this study was to investigate the biomechanical effect of varus and valgus malalignment on the tibial component under stance-phase gait cycle loading conditions.
methodsValidated finite element models for varus and valgus malalignment by 3° and 5° were developed to evaluate the effect of malalignment on the tibial component in TKA. Maximum contact stress and contact area on a polyethylene insert, maximum contact stress on patellar button and the collateral ligament force were investigated.
resultsThere was greater total contact stress in the varus alignment than in the valgus, with more marked difference on the medial side. An increase in ligament force was clearly demonstrated, especially in the valgus alignment and force exerted on the medial collateral ligament also increased.
conclusionThese results highlight the importance of accurate surgical reconstruction of the coronal tibial alignment of the knee joint. Varus and valgus alignments will influence wear and ligament stability, respectively in TKA.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.