Evidence map›Paper›PMID 29160390›Full record

ArticleArquivos brasileiros de cardiologia2017

Left Atrial Appendage Closure with Amplatzer Cardiac Plug in Nonvalvular Atrial Fibrillation: Safety and Long-Term Outcome.

Marcio José Montenegro da Costa, Esmeralci Ferreira, Edgard Freitas Quintella, Bernardo Amorim, Alexandre Fuchs, Ricardo Zajdenverg, Hugo Sabino, Denilson Campos de Albuquerque

Open access · diamondAbstract read
In one paragraph

Article in Arquivos brasileiros de cardiologia, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed, 1 pooled it
0.5field-weighted citation impact, top 29% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 1 synthesis or guideline pooled it, 4 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Observational
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 2 institutions in 1 country.

Marcio José Montenegro da CostaInstituto Estadual de Cardiologia Aloysio de Castro (IECAC); - Rio de Janeiro, RJ - Brazil.
Esmeralci FerreiraUniversidade do Estado do Rio de Janeiro (UERJ); - Rio de Janeiro, RJ - Brazil.
Edgard Freitas QuintellaInstituto Estadual de Cardiologia Aloysio de Castro (IECAC); - Rio de Janeiro, RJ - Brazil.
Bernardo AmorimInstituto Estadual de Cardiologia Aloysio de Castro (IECAC); - Rio de Janeiro, RJ - Brazil.
Alexandre FuchsInstituto Estadual de Cardiologia Aloysio de Castro (IECAC); - Rio de Janeiro, RJ - Brazil.
Ricardo ZajdenvergInstituto Estadual de Cardiologia Aloysio de Castro (IECAC); - Rio de Janeiro, RJ - Brazil.
Hugo SabinoInstituto Estadual de Cardiologia Aloysio de Castro (IECAC); - Rio de Janeiro, RJ - Brazil.
Denilson Campos de AlbuquerqueUniversidade do Estado do Rio de Janeiro (UERJ); - Rio de Janeiro, RJ - Brazil.
Instituto Estadual de Diabetes e Endocrinologia Luiz Capriglione · BRUniversidade do Estado do Rio de Janeiro · BR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundAtrial fibrillation (AF) is a cardiac arrhythmia with high risk for thromboembolic events, specially stroke.

objectiveTo assess the safety of left atrial appendage closure (LAAC) with the Amplatzer Cardiac Plug for the prevention of thromboembolic events in patients with nonvalvular AF.

methodsThis study included 15 patients with nonvalvular AF referred for LAAC, 6 older than 75 years (mean age, 69.4 ± 9.3 years; 60% of the male sex).

resultsThe mean CHADS2 score was 3.4 ± 0.1, and mean CHA2DS2VASc , 4.8 ± 1.8, evidencing a high risk for thromboembolic events. All patients had a HAS-BLED score > 3 (mean, 4.5 ± 1.2) with a high risk for major bleeding within 1 year. The device was successfully implanted in all patients, with correct positioning in the first attempt in most of them (n = 11; 73.3%).

conclusionThere was no periprocedural complication, such as device migration, pericardial tamponade, vascular complications and major bleeding. All patients had an uneventful in-hospital course, being discharged in 2 days. The echocardiographic assessments at 6 and 12 months showed neither device migration, nor thrombus formation, nor peridevice leak. On clinical assessment at 12 months, no patient had thromboembolic events or bleeding related to the device or risk factors. In this small series, LAAC with Amplatzer Cardiac Plug proved to be safe, with high procedural success rate and favorable outcome at the 12-month follow-up. (Arq Bras Cardiol. 2017; [online].ahead print, PP.0-0).

Indexed as

Septal Occluder DeviceAgedAtrial AppendageAtrial FibrillationCardiac CatheterizationEquipment SafetyFemaleHumansLongitudinal StudiesMaleRetrospective StudiesThromboembolismThrombosis

Identifiers

PMID29160390
PMCPMC5783435
OpenAlexW2766876850

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked