ArticleMedical & biological engineering & computing2018
Beat-to-beat estimation of stroke volume using impedance cardiography and artificial neural network.
Article in Medical & biological engineering & computing, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
- [Processing of impedance cardiogram differential for non-invasive cardiac function detection].Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi · 2019Article
- Novel characterization method of impedance cardiography signals using time-frequency distributions.Medical & biological engineering & computing · 2018Observational
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Impedance cardiography is a low-cost noninvasive technique, based on monitoring of the thoracic impedance, for estimation of stroke volume (SV). Impedance cardiogram (ICG) is the negative of the first derivative of the impedance signal. A technique for beat-to-beat SV estimation using impedance cardiography and artificial neural network (ANN) is proposed. A three-layer feed-forward ANN with error back-propagation algorithm is optimized by examining the effects of number of neurons in the hidden layer, activation function, training algorithm, and set of input parameters. The input parameters are obtained by automatic detection of the ICG characteristic points, and the target values are obtained by beat-to-beat SV measurements from time-aligned Doppler echocardiogram. The technique is evaluated using an ICG-echocardiography database with recordings from subjects with normal health in the under-rest and post-exercise conditions and from subjects with cardiovascular disorders in the under-rest condition. The proposed technique performed much better than the earlier established equation-based estimations, and it resulted in correlation coefficient of 0.93 for recordings from subjects with cardiovascular disorders. It may be helpful in improving the acceptability of impedance cardiography in clinical practice. Graphical abstract ᅟ.
Indexed as
Identifiers
29150800What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.