ArticleKnee surgery, sports traumatology, arthroscopy : official journal of the ESSKA2018
Consistency in patient-reported outcome measures after total knee arthroplasty using patient-specific instrumentation: a 5-year follow-up of 200 consecutive cases.
Article in Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
10 citing papers in PubMed, 19 citations in OpenAlex.
- In Vivo Kinematics for Various Robotically Performed Total Knee Arthroplasty Implant Designs.Journal of orthopaedic research : official publication of the Orthopaedic Research Society · 2025Article
- Physical Performance and Patient-Reported Outcomes Remain Stable at 5 Years After Total Knee Arthroplasty.Arthroscopy, sports medicine, and rehabilitation · 2025Article
- Satisfaction after total knee arthroplasty: a prospective matched-pair analysis of patients with customised individually made and off-the-shelf implants.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2023Article
- Cost-effectiveness of patient specificWorld journal of orthopedics · 2023Article
- Clinical outcomes after using patient specific instrumentation: is it worth the effort? A minimum 5-year retrospective review of 298 PSI knees.Archives of orthopaedic and trauma surgery · 2023Article
- Involving patients in the process: Development of a constipation patient-reported outcome measure for symptoms and quality of life.Computational and structural biotechnology journal · 2023Article
- No difference in patient-reported satisfaction after 12 months between customised individually made and off-the-shelf total knee arthroplasty.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2022Article
- Associations between Patient-Reported and Clinician-Reported Outcome Measures in Patients after Traumatic Injuries of the Lower Limb.International journal of environmental research and public health · 2022Article
- Mid-term functional outcomes of patient-specific versus conventional instrumentation total knee arthroplasty: a prospective study.Archives of orthopaedic and trauma surgery · 2021Article
- Comparable level of joint awareness between the bi-cruciate and cruciate retaining total knee arthroplasty with patient-specific instruments: a case-controlled study.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2020Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeThe purpose of this study was to evaluate the 5-year follow-up results of the first 200 total knee arthroplasties (TKA) performed by one high-volume surgeon, using patient-specific information (PSI). To date, there has been no other research into the mid-term follow-up of TKA performed using PSI. MATERIALS AND
methodsA total of 184 consecutive patients (200 TKA) were evaluated. Outcome measures included implant survival rate, adverse events, and the following patient-reported outcome measures (PROMs); Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), Oxford Knee Score (OKS), Pain Visual Analogue Score (VAS) and EuroQol-5D Score (EQ-5D).
resultsRevision surgery was performed for late secondary prosthetic joint infection (n = 1, total revision), aseptic loosening (n = 1, tibial component revision), instability (n = 1, isolated polyethylene insert exchange), and polyethylene insert breakage (n = 1, isolated polyethylene insert exchange). Other adverse events were as follows: debridement, antibiotics and implant retention for early prosthetic joint infection (n = 1), surgical debridement for haemarthrosis (n = 1), superficial wound infection (n = 2), thromboembolic events (n = 2), compartment syndrome (n = 1), and nerve injury (n = 2). All median outcome scores for patient reported outcome measures at 5 years improved significantly compared with the preoperative values (p ≤ 0.05). Median outcome scores were not significantly different between 1- and 5-year moments of follow-up, except for a significant decrease of EQ-VAS (p ≤ 0.05) between these two follow-up moments.
conclusionPROMs are consistent for 5-year follow-up of TKA using PSI. After 5 years of follow-up, revision surgery for any reason occurred in four patients (2%). LEVEL OF EVIDENCE: III.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.