Evidence map›Paper›PMID 29145437›Full record

ArticlePloS one2017

Assessment of the suitability of biodegradable rods for use in posterior lumbar fusion: An in-vitro biomechanical evaluation and finite element analysis.

Fon-Yih Tsuang, Yueh-Ying Hsieh, Yi-Jie Kuo, Chia-Hsien Chen, Feng-Huei Lin, Chen-Sheng Chen, Chang-Jung Chiang

Open access · goldAbstract read
In one paragraph

Article in PloS one, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
0.7field-weighted citation impact, top 28% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 15 citations in OpenAlex.

  1. Review
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 5 institutions in 1 country.

Fon-Yih TsuangInstitute of Biomedical Engineering, National Taiwan University, Taipei City, Taiwan.
Yueh-Ying HsiehDepartment of Orthopedics, Shuang Ho Hospital, Taipei Medical University, New Taipei City, Taiwan.
Yi-Jie KuoDepartment of Orthopedics, Taipei Medical University Hospital, Taipei City, Taiwan.
Chia-Hsien ChenDepartment of Orthopedics, Shuang Ho Hospital, Taipei Medical University, New Taipei City, Taiwan.
Feng-Huei LinInstitute of Biomedical Engineering, National Taiwan University, Taipei City, Taiwan.
Chen-Sheng ChenDepartment of Physical Therapy and Assistive Technology, National Yang-Ming University, Taipei, Taiwan.
Chang-Jung ChiangDepartment of Orthopedics, Shuang Ho Hospital, Taipei Medical University, New Taipei City, Taiwan.ORCID http://orcid.org/0000-0002-2269-8337
National Yang Ming Chiao Tung University · TWTaipei Medical University-Shuang Ho Hospital · TWNational Health Research Institutes · TWNational Taiwan University · TWTaipei Medical University Hospital · TW

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Interbody fusion with posterior instrumentation is a common method for treating lumbar degenerative disc diseases. However, the high rigidity of the fusion construct may produce abnormal stresses at the adjacent segment and lead to adjacent segment degeneration (ASD). As such, biodegradable implants are becoming more popular for use in orthopaedic surgery. These implants offer sufficient stability for fusion but at a reduced stiffness. Tailored to degrade over a specific timeframe, biodegradable implants could potentially mitigate the drawbacks of conventional stiff constructs and reduce the loading on adjacent segments. Six finite element models were developed in this study to simulate a spine with and without fixators. The spinal fixators used both titanium rods and biodegradable rods. The models were subjected to axial loading and pure moments. The range of motion (ROM), disc stresses, and contact forces of facet joints at adjacent segments were recorded. A 3-point bending test was performed on the biodegradable rods and a dynamic bending test was performed on the spinal fixators according to ASTM F1717-11a. The finite element simulation showed that lumbar spinal fusion using biodegradable implants had a similar ROM at the fusion level as at adjacent levels. As the rods degraded over time, this produced a decrease in the contact force at adjacent facet joints, less stress in the adjacent disc and greater loading on the anterior bone graft region. The mechanical tests showed the initial average fatigue strength of the biodegradable rods was 145 N, but this decreased to 115N and 55N after 6 months and 12 months of soaking in solution. Also, both the spinal fixator with biodegradable rods and with titanium rods was strong enough to withstand 5,000,000 dynamic compression cycles under a 145 N axial load. The results of this study demonstrated that biodegradable rods may present more favourable clinical outcomes for lumbar fusion. These polymer rods could not only provide sufficient initial stability, but the loss in rigidity of the fixation construct over time gradually transfers loading to adjacent segments.

Indexed as

Biocompatible MaterialsBiomechanical PhenomenaFinite Element AnalysisHumansIn Vitro TechniquesRange of Motion, ArticularSpinal FusionBiocompatible Materials

Identifiers

PMID29145437
PMCPMC5690668
OpenAlexW2768165659

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked