Evidence map›Paper›PMID 29139034›Full record

ArticleThe international journal of cardiovascular imaging2018

Vessel centerline reconstruction from non-isocentric and non-orthogonal paired monoplane angiographic images.

Mie Kunio, Caroline C O'Brien, Augusto C Lopes, Lynn Bailey, Pedro A Lemos, Guillermo J Tearney, Elazer R Edelman

Abstract readComparative StudyValidation Study
In one paragraph

Article in The international journal of cardiovascular imaging, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
1.0field-weighted citation impact, top 22% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 5 citations in OpenAlex.

  1. 3D localization from 2D X-ray projection.International journal of computer assisted radiology and surgery · 2022
    Article
  2. Article
  3. Cardiovascular imaging 2018 in the International Journal of Cardiovascular Imaging.The international journal of cardiovascular imaging · 2019
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 3 institutions in 2 countries.

Mie KunioMassachusetts Institute of Technology, 77 Massachusetts Avenue, E25-438, Cambridge, MA, 02139, USA. miek@mit.edu.ORCID http://orcid.org/0000-0003-0525-4723
Caroline C O'BrienMassachusetts Institute of Technology, 77 Massachusetts Avenue, E25-438, Cambridge, MA, 02139, USA.
Augusto C LopesMassachusetts Institute of Technology, 77 Massachusetts Avenue, E25-438, Cambridge, MA, 02139, USA.
Lynn BaileyCBSET, Inc., 500 Shire Way, Lexington, MA, USA.
Pedro A LemosHeart Institute (InCor), University of Sao Paulo Medical School, Sao Paulo, Brazil.
Guillermo J TearneyMassachusetts General Hospital, 55 Fruit Street, Bar 703, Boston, MA, USA.
Elazer R EdelmanMassachusetts Institute of Technology, 77 Massachusetts Avenue, E25-438, Cambridge, MA, 02139, USA.
Massachusetts Institute of Technology · USMassachusetts General Hospital · USUniversidade de São Paulo · BR

Funding

Vascular Drug Delivery - Supplement for EquipmentR01GM049039 · NIGMS · MASSACHUSETTS INSTITUTE OF TECHNOLOGY · PI EDELMAN, ELAZER R · 1994 to 2019
$8.9M
National Institutes of Health R01 GM49039NIGMS NIH HHS R01 GM049039
6 · The paper itself

Abstract

purposeThree-dimensional reconstruction of a vessel centerline from paired planar coronary angiographic images is critical to reconstruct the complex three-dimensional structure of the coronary artery lumen and the relative positioning of implanted devices. In this study, a new vessel centerline reconstruction method that can utilize non-isocentric and non-orthogonal pairs of angiographic images was developed and tested.

methodsOur new method was developed in in vitro phantom models of bifurcated coronary artery with and without stent, and then tested in in vivo swine models (twelve coronary arteries). This method was also validated using data from six patients.

resultsOur new method demonstrated high accuracy (root mean square error = 0.27 mm or 0.76 pixel), and high reproducibility across a broad imaging angle (20°-130°) and between different cardiac cycles in vitro and in vivo. Use of this method demonstrated that the vessel centerline in the stented segment did not deform significantly over a cardiac cycle in vivo. In addition, the total movement of the isocenter in each image could be accurately estimated in vitro and in vivo. The performance of this new method for patient data was similar to that for in vitro phantom models and in vivo animal models.

conclusionsWe developed a vessel centerline reconstruction method for non-isocentric and non-orthogonal angiographic images. It demonstrated high accuracy and good reproducibility in vitro, in vivo, and in clinical setting, suggesting that our new method is clinically applicable despite the small sample size of clinical data.

Indexed as

AlgorithmsAnimalsCoronary AngiographyCoronary Artery DiseaseCoronary VesselsDatabases, FactualHumansPercutaneous Coronary InterventionPhantoms, ImagingPredictive Value of TestsRadiographic Image Interpretation, Computer-AssistedReproducibility of ResultsRetrospective StudiesStentsSus scrofaCoronary angiographyImage reconstructionReconstruction algorithmStereoscopic theory

Identifiers

PMID29139034
PMCPMC5889725
OpenAlexW2770679904

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.