SynthesisScientific reports2017
Effect of titanium implants with strontium incorporation on bone apposition in animal models: A systematic review and meta-analysis.
Synthesis in Scientific reports, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
11 citing papers in PubMed, 1 synthesis or guideline pooled it, 36 citations in OpenAlex.
- Effectiveness of strontium/silver-based titanium surface coatings in improving antibacterial and osteogenic implant characteristics: a systematic review ofFrontiers in bioengineering and biotechnology · 2024Pooled it
- Dual Antibacterial and Soft-Tissue-Integrative Effect of Combined Strontium Acetate and Silver Nitrate on Peri-Implant Environment: Insights from Multispecies Biofilms and a 3D Coculture Model.ACS applied materials & interfaces · 2025Article
- Sustained release of Sr and Ca from a micronanotopographic titanium surface improves osteoblast function.Biometals : an international journal on the role of metal ions in biology, biochemistry, and medicine · 2025Article
- Functionalized zeolite regulates bone metabolic microenvironment.Materials today. Bio · 2025Review
- Titania (TiONanoscale · 2024Article
- Titanium micro-nano textured surface with strontium incorporation improves osseointegration: an in vivo and in vitro study.Journal of applied oral science : revista FOB · 2024Article
- Bisphosphonate-incorporated coatings for orthopedic implants functionalization.Materials today. Bio · 2023Review
- The Role of Trace Elements and Minerals in Osteoporosis: A Review of Epidemiological and Laboratory Findings.Biomolecules · 2023Review
- The Impact of Dental Implant Surface Modifications on Osseointegration and Biofilm Formation.Journal of clinical medicine · 2021Review
- Effectiveness of Antibacterial Surfaces in Osseointegration of Titanium Dental Implants: A Systematic Review.Antibiotics (Basel, Switzerland) · 2021Review
- Application of a Strontium-Loaded, Phase-Transited Lysozyme Coating to a Titanium Surface to Enhance Osteogenesis and Osteoimmunomodulation.Medical science monitor : international medical journal of experimental and clinical research · 2019Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
This systematic review aims to assess the efficacy of titanium (Ti) implant surfaces with or without strontium (Sr) incorporation on osseointegration in animal experimental studies. An electronic search was conducted using databases of PubMed and EMBASE up to November 2016 to identify studies focusing on osseointegration of strontium-modified titanium implants following PRISMA criteria. The primary outcome was the percentage of bone-to-implant contact (BIC) around the implants with or without strontium-modified surface. Of the 1320 studies, 17 studies fulfilling the inclusion criteria were finally included. A random effect meta-analysis was conducted based on BIC in 17 studies, and the results demonstrated considerable heterogeneity (I² = 79%). A sensitivity analysis found that three studies using the same surface modification method were the major source of the heterogeneity. Therefore, exploratory subgroup analysis was performed. Subgroup one including 14 studies showed a standard mean differences (SMD) of 1.42 (95% CI, 1.13-1.71) with no heterogeneity (I² = 0.0%), while subgroup two including the other three studies showed a SMD of 9.49.95% CI, 7.51-11.47) with low heterogeneity (I² = 0.1%). Sr-modified implants in both subgroups showed significantly higher BIC than unmodified implants (P < 0.01). The results showed a statistically significant effect of Sr-modified titanium implant surfaces on osseointegration and bone apposition in animal models.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.