Evidence map›Paper›PMID 29137200›Full record

ArticleSensors (Basel, Switzerland)2017

A Lab-on-a-Chip-Based Non-Invasive Optical Sensor for Measuring Glucose in Saliva.

Dong Geon Jung, Daewoong Jung, Seong Ho Kong

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 26 papers.

0numbers the graph read from it
0cells of the map it votes in
26citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

26 citing papers in PubMed.

  1. Review
  2. Article
  3. Article
  4. Review
  5. Review
  6. Article
  7. Article
  8. Article
  9. Review
  10. Article
  11. Review
  12. Article
  13. Review
  14. Review
  15. Article
  16. Review
  17. Review
  18. Review
  19. Nanoplasmonic Strip Test for Salivary Glucose Monitoring.Nanomaterials (Basel, Switzerland) · 2021
    Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Dong Geon JungGraduate School of Electronics Engineering, Kyungpook National University; Daegu 41566, Korea. max700128@hanmail.net.
Daewoong JungAircraft System Technology Group, Korea Institute of Industrial Technology (KITECH); Daegu 42994, Korea. dwjung@kitech.re.kr.
Seong Ho KongGraduate School of Electronics Engineering, Kyungpook National University; Daegu 41566, Korea. shkong@knu.ac.kr.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

A lab-on-a-chip (LOC)-based non-invasive optical sensor for measuring glucose in saliva was fabricated. Existing glucose sensors utilizing blood require acquisition of a blood sample by pricking the finger, which is painful and inconvenient. To overcome these limitations, we propose a non-invasive glucose sensor with LOC, micro-electro-mechanical system and optical measurement technology. The proposed sensor for measuring glucose in saliva involves pretreatment, mixing, and measurement on a single tiny chip. Saliva containing glucose and glucose oxidase for glucose oxidation are injected through Inlets 1 and 2, respectively. Next, H₂O₂ is produced by the reaction between glucose and glucose oxidase in the pretreatment part. The saliva and generated H₂O₂ are mixed with a colorizing agent injected through Inlet 3 during the mixing part and the absorbance of the colorized mixture is measured in the measurement part. The absorbance of light increases as a function of glucose concentration at a wavelength of 630 nm. To measure the absorbance of the colorized saliva, a light-emitting diode with a wavelength of 630 nm and a photodiode were used during the measurement part. As a result, the measured output current of the photodiode decreased as glucose concentration in the saliva increased.

Indexed as

Lab-On-A-Chip DevicesEquipment DesignGlucoseHydrogen PeroxideSalivaGlucoseHydrogen Peroxideglucoseoptical sensorsaliva

Identifiers

PMID29137200
PMCPMC5713136

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.