Evidence map›Paper›PMID 29136282›Full record

ArticleMedical physics2018

Principal component reconstruction (PCR) for cine CBCT with motion learning from 2D fluoroscopy.

Hao Gao, Yawei Zhang, Lei Ren, Fang-Fang Yin

Open access · greenAbstract read
In one paragraph

Article in Medical physics, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
1.9field-weighted citation impact, top 14% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 17 citations in OpenAlex.

  1. Article
  2. Article
  3. Review
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 2 countries.

Hao GaoDepartment of Radiation Oncology, Duke University Medical Center, Durham, NC, 27710, USA.
Yawei ZhangDepartment of Radiation Oncology, Duke University Medical Center, Durham, NC, 27710, USA.
Lei RenDepartment of Radiation Oncology, Duke University Medical Center, Durham, NC, 27710, USA.
Fang-Fang YinDepartment of Radiation Oncology, Duke University Medical Center, Durham, NC, 27710, USA.
Duke Medical Center · USDuke University Hospital · US

Funding

A Limited-angle Intra-fractional Verification (LIVE) System for SBRT TreatmentsR01CA184173 · NCI · DUKE UNIVERSITY · PI REN, LEI, YIN, FANG-FANG · 2015 to 2018
$1.5M
NCI NIH HHS R01 CA184173
6 · The paper itself

Abstract

purposeThis work aims to generate cine CT images (i.e., 4D images with high-temporal resolution) based on a novel principal component reconstruction (PCR) technique with motion learning from 2D fluoroscopic training images.

methodsIn the proposed PCR method, the matrix factorization is utilized as an explicit low-rank regularization of 4D images that are represented as a product of spatial principal components and temporal motion coefficients. The key hypothesis of PCR is that temporal coefficients from 4D images can be reasonably approximated by temporal coefficients learned from 2D fluoroscopic training projections. For this purpose, we can acquire fluoroscopic training projections for a few breathing periods at fixed gantry angles that are free from geometric distortion due to gantry rotation, that is, fluoroscopy-based motion learning. Such training projections can provide an effective characterization of the breathing motion. The temporal coefficients can be extracted from these training projections and used as priors for PCR, even though principal components from training projections are certainly not the same for these 4D images to be reconstructed. For this purpose, training data are synchronized with reconstruction data using identical real-time breathing position intervals for projection binning. In terms of image reconstruction, with a priori temporal coefficients, the data fidelity for PCR changes from nonlinear to linear, and consequently, the PCR method is robust and can be solved efficiently. PCR is formulated as a convex optimization problem with the sum of linear data fidelity with respect to spatial principal components and spatiotemporal total variation regularization imposed on 4D image phases. The solution algorithm of PCR is developed based on alternating direction method of multipliers.

resultsThe implementation is fully parallelized on GPU with NVIDIA CUDA toolbox and each reconstruction takes about a few minutes. The proposed PCR method is validated and compared with a state-of-art method, that is, PICCS, using both simulation and experimental data with the on-board cone-beam CT setting. The results demonstrated the feasibility of PCR for cine CBCT and significantly improved reconstruction quality of PCR from PICCS for cine CBCT.

conclusionWith a priori estimated temporal motion coefficients using fluoroscopic training projections, the PCR method can accurately reconstruct spatial principal components, and then generate cine CT images as a product of temporal motion coefficients and spatial principal components.

Indexed as

Cone-Beam Computed TomographyFluoroscopyFour-Dimensional Computed TomographyMachine LearningMovementArtifactsImage Processing, Computer-Assisted4D CBCT4D CTcompressive sensingimage reconstructionlow-rank

Identifiers

PMID29136282
PMCPMC6027657
OpenAlexW2769931151

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.