Evidence map›Paper›PMID 29134356›Full record

ArticleEuropean radiology2018

Secretin-stimulated ultrasound estimation of pancreatic secretion in cystic fibrosis validated by magnetic resonance imaging.

Trond Engjom, Erling Tjora, Gaute Wathle, Friedemann Erchinger, Birger N Lærum, Odd H Gilja, Ingfrid Salvesen Haldorsen, Georg Dimcevski

Open access · hybridAbstract read
In one paragraph

Article in European radiology, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
1.0field-weighted citation impact, top 21% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 5 citations in OpenAlex.

  1. Review
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 3 institutions in 1 country.

Trond EngjomDepartment of Clinical Medicine, University of Bergen, Bergen, Norway. trond.engjom@helse-bergen.no.ORCID http://orcid.org/0000-0002-2207-5455
Erling TjoraPediatric Department, Haukeland University Hospital, Bergen, Norway.
Gaute WathleDepartment of Radiology, Haukeland University Hospital, 5021, Bergen, Norway.
Friedemann ErchingerDepartment of Clinical Medicine, University of Bergen, Bergen, Norway.
Birger N LærumDepartment of Clinical Science, University of Bergen, 5021, Bergen, Norway.
Odd H GiljaDepartment of Clinical Medicine, University of Bergen, Bergen, Norway.
Ingfrid Salvesen HaldorsenDepartment of Clinical Medicine, University of Bergen, Bergen, Norway.
Georg DimcevskiDepartment of Clinical Medicine, University of Bergen, Bergen, Norway.
Haukeland University Hospital · NOÅlesund Hospital · NOUniversity of Bergen · NO

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesSecretin-stimulated magnetic resonance imaging (s-MRI) is the best validated radiological modality assessing pancreatic secretion. The purpose of this study was to compare volume output measures from secretin-stimulated transabdominal ultrasonography (s-US) to s-MRI for the diagnosis of exocrine pancreatic failure in cystic fibrosis (CF).

methodsWe performed transabdominal ultrasonography and MRI before and at timed intervals during 15 minutes after secretin stimulation in 21 CF patients and 13 healthy controls. To clearly identify the subjects with reduced exocrine pancreatic function, we classified CF patients as pancreas-sufficient or -insufficient by secretin-stimulated endoscopic short test and faecal elastase.

resultsPancreas-insufficient CF patients had reduced pancreatic secretions compared to pancreas-sufficient subjects based on both imaging modalities (p < 0.001). Volume output estimates assessed by s-US correlated to that of s-MRI (r = 0.56-0.62; p < 0.001). Both s-US (AUC: 0.88) and s-MRI (AUC: 0.99) demonstrated good diagnostic accuracy for exocrine pancreatic failure.

conclusionsPancreatic volume-output estimated by s-US corresponds well to exocrine pancreatic function in CF patients and yields comparable results to that of s-MRI. s-US provides a simple and feasible tool in the assessment of pancreatic secretion. KEY POINTS: • Cystic fibrosis patients with affected pancreas have reduced pancreatic secretions. • Secretin-stimulated sonography is a simple and feasible method to assess pancreatic output. • Secretin-simulated MRI is a more precise method to assess pancreatic secretions. • The sonographic and MRI methods yielded comparable pancreatic secretory output estimates.

Indexed as

AdultCystic FibrosisEndoscopyExocrine Pancreatic InsufficiencyFemaleHumansMagnetic Resonance ImagingMalePancreas, ExocrinePancreatic JuiceSecretinUltrasonographySecretinCystic fibrosisExocrine pancreatic insufficiencyMagnetic resonance imagingSecretinUltrasonography

Identifiers

PMID29134356
PMCPMC5834563
OpenAlexW2770434132

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.