ArticleInternational journal of mass spectrometry2017

Single Particle Analyzer of Mass: A Charge Detection Mass Spectrometer with a Multi-Detector Electrostatic Ion Trap.

Andrew G Elliott, Samuel I Merenbloom, Satrajit Chakrabarty, Evan R Williams

Abstract read
In one paragraph

Article in International journal of mass spectrometry, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 34 papers.

0numbers the graph read from it
0cells of the map it votes in
34citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

34 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Review
  7. Article
  8. Article
  9. Review
  10. Article
  11. Article
  12. Nonlinear dynamics of in-plane ring resonator for mass sensing.Microsystem technologies : sensors, actuators, systems integration · 2025
    Article
  13. Article
  14. Article
  15. Article
  16. Article
  17. Article
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Andrew G ElliottDepartment of Chemistry, University of California, Berkeley, California, 94720-1460.
Samuel I MerenbloomDepartment of Chemistry, University of California, Berkeley, California, 94720-1460.
Satrajit ChakrabartyDepartment of Chemistry, University of California, Berkeley, California, 94720-1460.
Evan R WilliamsDepartment of Chemistry, University of California, Berkeley, California, 94720-1460.

Funding

Development of Single Particle Analyzer of Mass and Mobility (SPAMM)R01GM096097 · NIGMS · UNIVERSITY OF CALIFORNIA BERKELEY · PI WILLIAMS, EVAN R · 2011 to 2014
$1.1M
Ion Mobility Spectrometry-Tandem Mass Spectrometry for Conformer Selective StructF32GM093593 · NIGMS · UNIVERSITY OF CALIFORNIA BERKELEY · PI MERENBLOOM, SAMUEL ISIAH · 2010 to 2012
$146k
NIGMS NIH HHS F32 GM093593NIGMS NIH HHS R01 GM096097
6 · The paper itself

Abstract

A new charge detection mass spectrometer that combines array detection and electrostatic ion trapping to repeatedly measure the masses of single ions is described. This instrument has four detector tubes inside an electrostatic ion trap with conical electrodes (cone trap) to provide multiple measurements of an ion on each pass through the trap resulting in a signal gain over a conventional trap with a single detection tube. Simulations of a cone trap and a dual ion mirror trap design indicate that more passes through the trap per unit time are possible with the latter. However, the cone trap has the advantages that ions entering up to 2 mm off the central axis of the trap are still trapped, the trapping time is less sensitive to the background pressure, and only a narrow range of energies are trapped so it can be used for energy selection. The capability of this instrument to obtain information about the molecular weight distributions of heterogeneous high molecular weight samples is demonstrated with 8 MDa polyethylene glycol (PEG) and 50 and 100 nm amine modified polystyrene nanoparticle samples. The measured mass distribution of the PEG sample is centered at 8 MDa. The size distribution obtained from mass measurements of the 100 nm nanoparticle sample is similar to the size distribution obtained from transmission electron microscopy (TEM) images, but most of the smaller nanoparticles observed in TEM images of the 50 nm nanoparticles do not reach a sufficiently high charge to trigger the trap on a single pass and be detected by the mass spectrometer. With the maximum trapping time set to 100 ms, the charge uncertainty is as low as ±2 charges and the mass uncertainty is approximately 2% for PEG and polystyrene ions.