Evidence map›Paper›PMID 29124286›Full record

ArticleKnee surgery, sports traumatology, arthroscopy : official journal of the ESSKA2018

Adjustable loop ACL suspension devices demonstrate less reliability in terms of reproducibility and irreversible displacement.

Sufian S Ahmad, Michael T Hirschmann, Benjamin Voumard, Sandro Kohl, Philippe Zysset, Takura Mukabeta, Dimitrios S Evangelopoulos, Atesch Ateschrang

Abstract readComparative Study
PubMed Publisher
In one paragraph

Article in Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 18 papers.

0numbers the graph read from it
0cells of the map it votes in
18citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

18 citing papers in PubMed.

  1. Article
  2. Observational
  3. Article
  4. Article
  5. Article
  6. Article
  7. Comparison of the mechanical properties and mechanical damages to tendon tissue in three suspensory fixation techniques.Asia-Pacific journal of sports medicine, arthroscopy, rehabilitation and technology · 2022
    Article
  8. Article
  9. Article
  10. Suspension button constructs restore posterior knee laxity in solid tibial avulsion of the posterior cruciate ligament.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2021
    Article
  11. Clinical and radiographic results after ACL reconstruction using an adjustable-loop device.Asia-Pacific journal of sports medicine, arthroscopy, rehabilitation and technology · 2021
    Article
  12. Article
  13. Article
  14. Review
  15. Article
  16. Article
  17. Article
  18. Adjustable buttons for ACL graft cortical fixation partially fail with cyclic loading and unloading.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2019
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Sufian S AhmadDepartment of Orthopaedic Surgery and Traumatology, Inselspital, University Hospital of Berne, Berne, Switzerland. sufiansamy@gmail.com.
Michael T HirschmannDepartment of Orthopaedic Surgery and Traumatology, Kantonsspital Baselland (Bruderholz, Liestal, Laufen), Bruderholz, Switzerland.
Benjamin VoumardInstitute for Surgical Technology and Biomechanics (ISTB), University of Berne, Berne, Switzerland.
Sandro KohlDepartment of Orthopaedic Surgery and Traumatology, Inselspital, University Hospital of Berne, Berne, Switzerland.
Philippe ZyssetInstitute for Surgical Technology and Biomechanics (ISTB), University of Berne, Berne, Switzerland.
Takura MukabetaDepartment of Orthopaedic Surgery and Traumatology, Groote Schuur University Hospital of Cape Town, University of Cape Town, Cape Town, South Africa.
Dimitrios S EvangelopoulosDepartment of Orthopaedic Surgery and Traumatology, Inselspital, University Hospital of Berne, Berne, Switzerland.
Atesch AteschrangDepartment of Traumatology and Reconstructive Surgery, BG Trauma Center Tübingen, Eberhard-Karls University of Tübingen, Tübingen, Germany.

Funding

MEDACTA Corporate N/A
6 · The paper itself

Abstract

purposeThe aim of this study was to perform a comprehensive biomechanical examination of frequently applied femoral cortical suspension devices, comparing the properties of both fixed and adjustable fixation mechanisms. It was hypothesized that adjustable loop devices demonstrate less consistent fixation properties with increased variability compared to fixed loop devices.

methodsNine frequently applied fixation button types were tested, six adjustable and three rigid loop devices. Six samples of each device type were purchased. Each device was installed in a servo-hydraulic mechanical testing machine, running a 2000 cycle loading protocol at force increments between 50 and 500 N. Irreversible displacement in mm was measured for all of the tested samples of each implant. Ultimately, maximum load to failure was applied and measured in Nm. An irreversible displacement of 3 mm was considered failure of the implant.

resultsThree of the six adjustable devices (GraftMax™, TightRope® ToggleLoc™) demonstrated a median displacement above the threshold of clinical failure before completion of the cycles. All adjustable loop devices showed a wide intragroup variation in terms of irreversible displacement, compared to fixed-loop devices. Fixed-loop devices provided consistent reproducible results with narrow ranges and significantly lower irreversible displacement (p < 0.05), the maximum being 1.4 mm. All devices withstood an ultimate force of more than 500 N.

conclusionAdjustable loop devices still show biomechanical inferiority and demonstrate heterogeneity of fixation properties with wide- and less-reproducible displacement ranges resultant to the mechanism of adjustment, denoting less reliability. However, three adjustable devices (RIGIDLOOP™ Adjustable, Ultrabutton

Indexed as

Orthopedic Fixation DevicesAnterior Cruciate Ligament ReconstructionBiomechanical PhenomenaEquipment DesignHumansReproducibility of ResultsACL reconstructionACL repairACL TightRope®Adjustable buttonENDOBUTTON◊ CL ULTRAFemoral cortical suspension deviceFixed buttonGraftMax™Irreversible displacementProCinch™RetroButtonRIGIDLOOPRIGIDLOOP™ AdjustableToggleLoc™Ultrabutton◊

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.