Evidence map›Paper›PMID 29122759›Full record

ArticleAJNR. American journal of neuroradiology2018

Diffusion-Weighted Imaging of the Head and Neck: Influence of Fat-Suppression Technique and Multishot 2D Navigated Interleaved Acquisitions.

Y J Bae, B S Choi, H-K Jeong, L Sunwoo, C Jung, J H Kim

Abstract read
In one paragraph

Article in AJNR. American journal of neuroradiology, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Advances in magnetic resonance imaging of orbital disease.Canadian journal of ophthalmology. Journal canadien d'ophtalmologie · 2022
    Article
  7. Regularized joint water-fat separation with BMagnetic resonance in medicine · 2021
    Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Y J BaeFrom the Department of Radiology (Y.J.B., B.S.C., L.S., C.J., J.H.K.), Seoul National University Bundang Hospital, Seongnam, Republic of Korea.ORCID 0000-0002-1779-4949
B S ChoiFrom the Department of Radiology (Y.J.B., B.S.C., L.S., C.J., J.H.K.), Seoul National University Bundang Hospital, Seongnam, Republic of Korea byungse.choi@gmail.com.ORCID 0000-0001-6310-1798
H-K JeongPhilips Korea (H.-K.J.), Seoul, Republic of Korea.ORCID 0000-0002-6037-8342
L SunwooFrom the Department of Radiology (Y.J.B., B.S.C., L.S., C.J., J.H.K.), Seoul National University Bundang Hospital, Seongnam, Republic of Korea.ORCID 0000-0003-0374-8658
C JungFrom the Department of Radiology (Y.J.B., B.S.C., L.S., C.J., J.H.K.), Seoul National University Bundang Hospital, Seongnam, Republic of Korea.ORCID 0000-0002-8862-7347
J H KimFrom the Department of Radiology (Y.J.B., B.S.C., L.S., C.J., J.H.K.), Seoul National University Bundang Hospital, Seongnam, Republic of Korea.ORCID 0000-0002-0545-4138

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

background and purposeDWI of the head and neck can reveal valuable information, but the effects of fat suppression and multishot acquisition on image quality have not been thoroughly investigated. We aimed to comprehensively compare the quality of head and neck DWI at 3T using 2 fat-suppression techniques, STIR, and spectral presaturation with inversion recovery, which were used with both single- and multishot EPI. MATERIALS AND

methodsSixty-five study participants underwent 3 DWI sequences of single-shot EPI-STIR, single-shot EPI-spectral presaturation with inversion recovery, and multishot EPI-spectral presaturation with inversion recovery of the head and neck. In multiple anatomic regions, 2 independent readers assessed 5-point visual scores for fat-suppression uniformity and image distortion, and 1 reader measured the contrast-to-noise ratio and ADC.

resultsThe mean visual score for fat-suppression uniformity was higher in single-shot EPI-STIR than in other sequences (all regions except for the orbital region,

conclusionsOverall, multishot EPI-spectral presaturation with inversion recovery provided the best image quality, with relatively homogeneous fat suppression, less image distortion than single-shot EPI sequences, and higher contrast-to-noise ratio than single-shot EPI-STIR. The measured ADC values can be higher in multishot EPI-spectral presaturation with inversion recovery, which necessitates cautious application of the previously reported ADC values to clinical settings.

Indexed as

AdultAgedAged, 80 and overDiffusion Magnetic Resonance ImagingEcho-Planar ImagingFemaleHeadHumansImage Interpretation, Computer-AssistedMaleMiddle AgedNeckReproducibility of ResultsRetrospective Studies

Identifiers

PMID29122759
PMCPMC7410699

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.