Evidence map›Paper›PMID 29119728›Full record

ArticleInternational journal for numerical methods in biomedical engineering2018

A framework for designing patient-specific bioprosthetic heart valves using immersogeometric fluid-structure interaction analysis.

Fei Xu, Simone Morganti, Rana Zakerzadeh, David Kamensky, Ferdinando Auricchio, Alessandro Reali, Thomas J R Hughes, Michael S Sacks, Ming-Chen Hsu

Abstract read
In one paragraph

Article in International journal for numerical methods in biomedical engineering, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 41 papers.

0numbers the graph read from it
0cells of the map it votes in
41citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

41 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Review
  16. Article
  17. Article
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Fei XuDepartment of Mechanical Engineering, Iowa State University, 2025 Black Engineering, Ames, IA 50011, USA.ORCID 0000-0001-5361-4231
Simone MorgantiDepartment of Electrical, Computer, and Biomedical Engineering, University of Pavia, via Ferrata 3, 27100 Pavia, Italy.
Rana ZakerzadehCenter for Cardiovascular Simulation, Institute for Computational Engineering and Sciences, The University of Texas at Austin, 201 East 24th St, Stop C0200, Austin, TX 78712, USA.ORCID 0000-0003-0927-8896
David KamenskyDepartment of Structural Engineering, University of California, San Diego, 9500 Gilman Drive, Mail Code 0085, La Jolla, CA 92093, USA.
Ferdinando AuricchioDepartment of Civil Engineering and Architecture, University of Pavia, via Ferrata 3, 27100 Pavia, Italy.
Alessandro RealiDepartment of Civil Engineering and Architecture, University of Pavia, via Ferrata 3, 27100 Pavia, Italy.
Thomas J R HughesCenter for Cardiovascular Simulation, Institute for Computational Engineering and Sciences, The University of Texas at Austin, 201 East 24th St, Stop C0200, Austin, TX 78712, USA.
Michael S SacksCenter for Cardiovascular Simulation, Institute for Computational Engineering and Sciences, The University of Texas at Austin, 201 East 24th St, Stop C0200, Austin, TX 78712, USA.ORCID 0000-0003-0198-9212
Ming-Chen HsuDepartment of Mechanical Engineering, Iowa State University, 2025 Black Engineering, Ames, IA 50011, USA.ORCID 0000-0001-8062-8612

Funding

Novel Simulation Technologies for BHV Long-Term DurabilityR01HL129077 · NHLBI · UNIVERSITY OF TEXAS AT AUSTIN · PI HUGHES, THOMAS J., MANNING, KEEFE B · 2016 to 2019
$2.1M
NHLBI NIH HHS R01 HL129077
6 · The paper itself

Abstract

Numerous studies have suggested that medical image derived computational mechanics models could be developed to reduce mortality and morbidity due to cardiovascular diseases by allowing for patient-specific surgical planning and customized medical device design. In this work, we present a novel framework for designing prosthetic heart valves using a parametric design platform and immersogeometric fluid-structure interaction (FSI) analysis. We parameterize the leaflet geometry using several key design parameters. This allows for generating various perturbations of the leaflet design for the patient-specific aortic root reconstructed from the medical image data. Each design is analyzed using our hybrid arbitrary Lagrangian-Eulerian/immersogeometric FSI methodology, which allows us to efficiently simulate the coupling of the deforming aortic root, the parametrically designed prosthetic valves, and the surrounding blood flow under physiological conditions. A parametric study is performed to investigate the influence of the geometry on heart valve performance, indicated by the effective orifice area and the coaptation area. Finally, the FSI simulation result of a design that balances effective orifice area and coaptation area reasonably well is compared with patient-specific phase contrast magnetic resonance imaging data to demonstrate the qualitative similarity of the flow patterns in the ascending aorta.

Indexed as

Heart Valve ProsthesisProsthesis DesignComputer SimulationHeart ValvesHeart VentriclesHemorheologyHumansModels, CardiovascularTime Factorsbioprosthetic heart valvesfluid-structure interactionimmersogeometric analysisisogeometric analysisparametric designpatient specific

Identifiers

PMID29119728
PMCPMC5893448

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.