Evidence map›Paper›PMID 29118899›Full record

ReviewAmerican journal of translational research2017

Alterations in tendon microenvironment in response to mechanical load: potential molecular targets for treatment strategies.

Mohamed B Fouda, Finosh G Thankam, Matthew F Dilisio, Devendra K Agrawal

Abstract readReview
In one paragraph

Review in American journal of translational research, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 25 papers.

0numbers the graph read from it
0cells of the map it votes in
25citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

25 citing papers in PubMed.

  1. Article
  2. Tendinopathy: The Interplay between Mechanical Stress, Inflammation, and Vascularity.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2025
    Review
  3. Article
  4. Article
  5. Article
  6. Review
  7. Risk factors for incisional hernia after gastrointestinal surgeries in non-tumor patients.Hernia : the journal of hernias and abdominal wall surgery · 2024
    Article
  8. Article
  9. Article
  10. Review
  11. Article
  12. Article
  13. Hyperlipidemia Lowers the Biomechanical Properties of Rotator Cuff Tendon.Journal of orthopaedics and sports medicine · 2023
    Article
  14. Article
  15. Review
  16. Age-related cellular and microstructural changes in the rotator cuff enthesis.Journal of orthopaedic research : official publication of the Orthopaedic Research Society · 2022
    Article
  17. The role of loading in murine models of rotator cuff disease.Journal of orthopaedic research : official publication of the Orthopaedic Research Society · 2022
    Article
  18. Article
  19. [Application of medical biomaterials in prevention and treatment of tendon adhesion].Zhongguo xiu fu chong jian wai ke za zhi = Zhongguo xiufu chongjian waike zazhi = Chinese journal of reparative and reconstructive surgery · 2020
    Review
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Mohamed B FoudaDepartment of Clinical & Translational Science, Creighton University School of MedicineOmaha 68178, NE, USA.
Finosh G ThankamDepartment of Clinical & Translational Science, Creighton University School of MedicineOmaha 68178, NE, USA.
Matthew F DilisioDepartment of Clinical & Translational Science, Creighton University School of MedicineOmaha 68178, NE, USA.
Devendra K AgrawalDepartment of Clinical & Translational Science, Creighton University School of MedicineOmaha 68178, NE, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Rotator cuff (RC) tendons could beinflicted in many ways with an eventual outcome of pain, weakness and disability, which represent a large burden on health care cost. However, optimal healing, either conservatively or with surgical intervention, remains an issue that needs further investigation. Disorders of the RC tendons may result from external factors like trauma, or internal factors through physiologic and metabolic derangement. Most RC tendon disorders may be asymptomatic and may result from an over-activity of the inflicted shoulder and its tendons. Such tendon disorders are poorly diagnosed since patients do not seek medical attention until pain or weakness ensue. Immunological and biochemical events in RC disorders due to mechanical intolerance have not been investigated. Generally, the mechanical load drives normal physiological properties of the tendon. But, mechanical overload/burden exerts stress on tenocytes, and disrupts the tendon microenvironment by triggering a multitude of signaling pathways leading to extracellular matrix remodeling, disorganization, alteration in collagen composition and apoptosis. These events result in weak tendon which is highly susceptible to rupture or tear. In this article, we critically reviewed the intrinsic signaling pathways that are excessively triggered by continuous mechanical load and the counteracting physiological responses and associated derangements. The elucidation of the molecular events underlying mechanical stress-induced symptomatic/asymptomatic tendinopathy could provide information on potential target sites for translational application in the management of rotator cuff disorders.

Indexed as

Collagen depositionextracellular matrixmechanical loadrotator cuff injurytendinopathytenocytes

Identifiers

PMID29118899
PMCPMC5666046

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.