Evidence map›Paper›PMID 29118794›Full record

ArticleInterventional neurology2017

Safety and Efficacy of Low-Profile, Self-Expandable Stents for Treatment of Intracranial Aneurysms: Initial and Midterm Results - A Systematic Review and Meta-Analysis.

Su-Yeon Park, Jae-Sang Oh, Hyuk-Jin Oh, Seok-Mann Yoon, Hack-Gun Bae

Open access · bronzeAbstract read
In one paragraph

Article in Interventional neurology, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 16 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
16citing papers in PubMed, 1 pooled it
1.8field-weighted citation impact, top 16% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

16 citing papers in PubMed, 1 synthesis or guideline pooled it, 25 citations in OpenAlex.

  1. Pooled it
  2. Contour device implantation for treatment of intracranial aneurysms in the basilar tip.Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2026
    Article
  3. Article
  4. Long-term results of wide-necked intracranial bifurcation aneurysms treated with stent-assisted coiling using low-profile acandis acclino stents.Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2023
    Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Review
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Su-Yeon ParkDepartment of Statistics, Soonchunhyang University Hospital Cheonan, Cheonan, Republic of Korea.
Jae-Sang OhDepartment of Neurosurgery, Soonchunhyang University Hospital Cheonan, Cheonan, Republic of Korea.
Hyuk-Jin OhDepartment of Neurosurgery, Soonchunhyang University Hospital Cheonan, Cheonan, Republic of Korea.
Seok-Mann YoonDepartment of Neurosurgery, Soonchunhyang University Hospital Cheonan, Cheonan, Republic of Korea.
Hack-Gun BaeDepartment of Neurosurgery, Soonchunhyang University Hospital Cheonan, Cheonan, Republic of Korea.
Soonchunhyang University · KR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Low-profile stents seem to be associated with a higher incidence of thromboembolic events compared with preexisting stents. We conducted a systematic review of 11 eligible reports and a meta-analysis of 7 reports with respect to the clinical efficacy and safety of low-profile stents. There were 217 intracranial aneurysms reported; 22% were ruptured aneurysms. In all, 72% were treated using single stenting, 19% were treated using overlapping stenting, and 6% were treated using balloon angioplasty followed by stenting; 3% were used to assess the flow diverter effect in a dissecting aneurysm or were treated using unexpected subtotal coil packing. On immediate postprocedural angiographic results, Raymond class I and II obliteration was obtained in 87% of the aneurysms. On angiographic results at 3-6 months, Raymond class I and II obliteration or stability was obtained in 79% of the aneurysms, and Raymond class III obliteration was obtained in 3% of the aneurysms. The recurrence rate on follow-up of intracranial aneurysms was 6.5% (5.7% with LEO Baby and 1.3% with LVIS Jr). The periprocedural complication rate was 12.4%. Periprocedural thromboembolism occurred in 6.5% of the cases. The rate of in-stent stenosis on follow-up of intracranial aneurysms was 10%. In the midterm result, the recurrence rate with use of low-profile, self-expandable stents was relatively low compared to that with use of other self-expandable stents. In the meta-analysis comparing LEO Baby with LVIS Jr, the obliteration rate at 6 months was not significantly different, but the periprocedural complication rate was relatively low with LVIS Jr.

Indexed as

Intracranial aneurysmLow-profile stentRecurrenceStent-assisted coilThromboembolism

Identifiers

PMID29118794
PMCPMC5662986
OpenAlexW2608845563

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked