Evidence map›Paper›PMID 29115692›Full record

ArticleMagnetic resonance in medicine2018

A spiral-based volumetric acquisition for MR temperature imaging.

Samuel W Fielden, Xue Feng, Li Zhao, G Wilson Miller, Matthew Geeslin, Robert F Dallapiazza, W Jeffrey Elias, Max Wintermark, Kim Butts Pauly, Craig H Meyer

Open access · greenAbstract read
In one paragraph

Article in Magnetic resonance in medicine, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers.

0numbers the graph read from it
0cells of the map it votes in
13citing papers in PubMed
0.9field-weighted citation impact, top 26% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

13 citing papers in PubMed, 20 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Technical advances in motion-robust MR thermometry.Magnetic resonance in medicine · 2024
    Review
  6. Motion-robust, multi-slice, real-time MR thermometry for MR-guided thermal therapy in abdominal organs.International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group · 2023
    Article
  7. Article
  8. Real-Time Magnetic Resonance Imaging.Journal of magnetic resonance imaging : JMRI · 2022
    Review
  9. Article
  10. Article
  11. Article
  12. Article
  13. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 2 institutions in 1 country.

Samuel W FieldenDepartment of Biomedical Engineering, University of Virginia, Charlottesville, Virginia, USA.
Xue FengDepartment of Biomedical Engineering, University of Virginia, Charlottesville, Virginia, USA.
Li ZhaoDepartment of Biomedical Engineering, University of Virginia, Charlottesville, Virginia, USA.ORCID 0000-0003-4933-3183
G Wilson MillerDepartment of Radiology and Medical Imaging, University of Virginia, Charlottesville, Virginia, USA.
Matthew GeeslinDepartment of Radiology and Medical Imaging, University of Virginia, Charlottesville, Virginia, USA.
Robert F DallapiazzaDepartment of Neurosurgery, University of Virginia, Charlottesville, Virginia, USA.
W Jeffrey EliasDepartment of Neurosurgery, University of Virginia, Charlottesville, Virginia, USA.
Max WintermarkDepartment of Radiology, Stanford University, Palo Alto, California, USA.
Kim Butts PaulyDepartment of Radiology, Stanford University, Palo Alto, California, USA.
Craig H MeyerDepartment of Biomedical Engineering, University of Virginia, Charlottesville, Virginia, USA.
University of Virginia · USPalo Alto University · US

Funding

Motion-Robust Methods for Rapid Pediatric MRI without SedationR21EB022309 · NIBIB · UNIVERSITY OF VIRGINIA · PI MEYER, CRAIG H · 2016 to 2018
$539k
NIBIB NIH HHS R21 EB022309
6 · The paper itself

Abstract

purposeTo develop a rapid pulse sequence for volumetric MR thermometry.

methodsSimulations were carried out to assess temperature deviation, focal spot distortion/blurring, and focal spot shift across a range of readout durations and maximum temperatures for Cartesian, spiral-out, and retraced spiral-in/out (RIO) trajectories. The RIO trajectory was applied for stack-of-spirals 3D imaging on a real-time imaging platform and preliminary evaluation was carried out compared to a standard 2D sequence in vivo using a swine brain model, comparing maximum and mean temperatures measured between the two methods, as well as the temporal standard deviation measured by the two methods.

resultsIn simulations, low-bandwidth Cartesian trajectories showed substantial shift of the focal spot, whereas both spiral trajectories showed no shift while maintaining focal spot geometry. In vivo, the 3D sequence achieved real-time 4D monitoring of thermometry, with an update time of 2.9-3.3 s.

conclusionSpiral imaging, and RIO imaging in particular, is an effective way to speed up volumetric MR thermometry. Magn Reson Med 79:3122-3127, 2018. © 2017 International Society for Magnetic Resonance in Medicine.

Indexed as

AnimalsBrainComputer SimulationImage Processing, Computer-AssistedMagnetic Resonance ImagingPhantoms, ImagingSwineThermometryMR-guided focused ultrasoundspiral imagingthermometry

Identifiers

PMID29115692
PMCPMC6377207
OpenAlexW2767349760

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked