ArticleMagnetic resonance in medicine2018
A spiral-based volumetric acquisition for MR temperature imaging.
Article in Magnetic resonance in medicine, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
13 citing papers in PubMed, 20 citations in OpenAlex.
- 3D MR Thermometry Using Bi-Directional Segmented EPI for Transcranial-Focused Ultrasound.Magnetic resonance in medicine · 2026Article
- Online Spatiotemporally Constrained Reconstruction for Real-Time Interactive MRI.Magnetic resonance in medicine · 2026Article
- A retraced spiral strategy with semi-automatic deblurring for volumetric thermometry.Magnetic resonance in medicine · 2025Article
- MR thermometry with high precision and temporal resolution by quadratic phase MR fingerprinting.Magnetic resonance in medicine · 2025Article
- Technical advances in motion-robust MR thermometry.Magnetic resonance in medicine · 2024Review
- Motion-robust, multi-slice, real-time MR thermometry for MR-guided thermal therapy in abdominal organs.International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group · 2023Article
- Comparison study of reconstruction algorithms for volumetric necrosis maps from 2D multi-slice GRE thermometry images.Scientific reports · 2022Article
- Real-Time Magnetic Resonance Imaging.Journal of magnetic resonance imaging : JMRI · 2022Review
- A System for Real-Time, Online Mixed-Reality Visualization of Cardiac Magnetic Resonance Images.Journal of imaging · 2021Article
- A Breast-Specific MR Guided Focused Ultrasound Platform and Treatment Protocol: First-in-Human Technical Evaluation.IEEE transactions on bio-medical engineering · 2021Article
- Correcting image blur in spiral, retraced in/out (RIO) acquisitions using a maximized energy objective.Magnetic resonance in medicine · 2019Article
- Improved MR thermometry for laser interstitial thermotherapy.Lasers in surgery and medicine · 2019Article
- Magnetic resonance thermometry and its biological applications - Physical principles and practical considerations.Progress in nuclear magnetic resonance spectroscopy · 2019Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors at 2 institutions in 1 country.
Funding
Abstract
purposeTo develop a rapid pulse sequence for volumetric MR thermometry.
methodsSimulations were carried out to assess temperature deviation, focal spot distortion/blurring, and focal spot shift across a range of readout durations and maximum temperatures for Cartesian, spiral-out, and retraced spiral-in/out (RIO) trajectories. The RIO trajectory was applied for stack-of-spirals 3D imaging on a real-time imaging platform and preliminary evaluation was carried out compared to a standard 2D sequence in vivo using a swine brain model, comparing maximum and mean temperatures measured between the two methods, as well as the temporal standard deviation measured by the two methods.
resultsIn simulations, low-bandwidth Cartesian trajectories showed substantial shift of the focal spot, whereas both spiral trajectories showed no shift while maintaining focal spot geometry. In vivo, the 3D sequence achieved real-time 4D monitoring of thermometry, with an update time of 2.9-3.3 s.
conclusionSpiral imaging, and RIO imaging in particular, is an effective way to speed up volumetric MR thermometry. Magn Reson Med 79:3122-3127, 2018. © 2017 International Society for Magnetic Resonance in Medicine.